A quality assurance phantom for electronic portal imaging devices

If you need an accessible version of this item, please submit a remediation request.
Date
2011
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
American Association of Physicists in Medicine
Abstract

Electronic portal imaging device (EPID) plays an important role in radiation therapy portal imaging, geometric and dosimetric verification. Consistent image quality and stable radiation response is necessary for proper utilization that requires routine quality assurance (QA). A commercial ‘EPID QC’ phantom weighing 3.8 kg with a dimension of 25 × 25 × 4.8 cm3 is used for EPID QA. This device has five essential tools to measure the geometric accuracy, signal‐to‐noise ratio (SNR), dose linearity, and the low‐ and the high‐contrast resolutions. It is aligned with beam divergence to measure the imaging and geometric parameters in both X and Y directions, and can be used as a baseline check for routine QA. The low‐contrast tool consists of a series of holes with various diameters and depths in an aluminum slab, very similar to the Las Vegas phantom. The high‐resolution contrast tool provides the modulation transfer function (MTF) in both the x‐ and y‐dimensions to measure the focal spot of linear accelerator that is important for imaging and small field dosimetry. The device is tested in different institutions with various amorphous silicon imagers including Elekta, Siemens and Varian units. Images of the QA phantom were acquired at 95.2 cm source‐skin‐distance (SSD) in the range 1–15 MU for a 26 × 26 cm2 field and phantom surface is set normal to the beam direction when gantry is at 0° and 90°. The epidSoft is a software program provided with the EPID QA phantom for analysis of the data. The preliminary results using the phantom on the tested EPID showed very good low‐contrast resolution and high resolution, and an MTF (0.5) in the range of 0.3–0.4 lp/mm. All imagers also exhibit satisfactory geometric accuracy, dose linearity and SNR, and are independent of MU and spatial orientations. The epidSoft maintains an image analysis record and provides a graph of the temporal variations in imaging parameters. In conclusion, this device is simple to use and provides testing on basic and advanced imaging parameters for daily QA on any imager used in clinical practices

Description
Keywords
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Das, I. J., Cao, M., Cheng, C., Misic, V., Scheuring, K., Schüle, E., & Johnstone, P. A. S. (2011). A quality assurance phantom for electronic portal imaging devices. Journal of Applied Clinical Medical Physics, 12(2), 391–403. http://doi.org/10.1120/jacmp.v12i2.3350
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Journal of Applied Clinical Medical Physics
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}