Highly sensitive lipid detection and localization in atherosclerotic plaque with a dual-frequency intravascular photoacoustic/ultrasound catheter

dc.contributor.authorCao, Yingchun
dc.contributor.authorAlloosh, Mouhamad
dc.contributor.authorSturek, Michael
dc.contributor.authorCheng, Ji-Xin
dc.contributor.departmentAnatomy, Cell Biology and Physiology, School of Medicine
dc.date.accessioned2024-03-08T10:26:18Z
dc.date.available2024-03-08T10:26:18Z
dc.date.issued2020
dc.description.abstractIntravascular photoacoustic/ultrasound (IVPA/US) is an emerging hybrid imaging modality that provides specific lipid detection and localization, while maintaining co-registered artery morphology, for diagnosis of vulnerable plaque in cardiovascular disease. However, current IVPA/US approaches based on a single-element transducer exhibit compromised performance for lipid detection due to the relatively low contrast of lipid absorption and conflicting detection bands for photoacoustic and ultrasound signals. Here, we present a dual-frequency IVPA/US catheter for highly sensitive detection and precision localization of lipids. The low frequency transducer provides enhanced photoacoustic sensitivity, while the high frequency transducer maintains state-of-the-art spatial resolution for ultrasound imaging. The boosted capability of IVPA/US imaging enables a multi-scale analysis of lipid distribution in swine with coronary atherosclerosis. The dual-frequency IVPA/US catheter has a diameter of 1 mm and flexibility to easily adapt to current catheterization procedures and is a significant step toward clinical diagnosis of vulnerable plaque.
dc.eprint.versionAuthor's manuscript
dc.identifier.citationCao Y, Alloosh M, Sturek M, Cheng JX. Highly sensitive lipid detection and localization in atherosclerotic plaque with a dual-frequency intravascular photoacoustic/ultrasound catheter. Transl Biophotonics. 2020;2(3):e202000004. doi:10.1002/tbio.202000004
dc.identifier.urihttps://hdl.handle.net/1805/39103
dc.language.isoen_US
dc.publisherWiley
dc.relation.isversionof10.1002/tbio.202000004
dc.relation.journalTranslational Biophotonics
dc.rightsPublisher Policy
dc.sourcePMC
dc.subjectAtherosclerotic plaque
dc.subjectDual-frequency
dc.subjectIntravascular photoacoustic
dc.subjectLipid core
dc.subjectOssabaw miniature swine
dc.titleHighly sensitive lipid detection and localization in atherosclerotic plaque with a dual-frequency intravascular photoacoustic/ultrasound catheter
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
nihms-1883077.pdf
Size:
2.65 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: