An effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: A case study

dc.contributor.authorAkino, Yuichi
dc.contributor.authorWu, Huanmei
dc.contributor.authorOh, Ryoong-Jin
dc.contributor.authorDas, Indra J.
dc.contributor.departmentBioHealth Informatics, School of Informatics and Computingen_US
dc.date.accessioned2019-06-26T18:21:59Z
dc.date.available2019-06-26T18:21:59Z
dc.date.issued2019-01
dc.description.abstractPURPOSE: For scanning particle beam therapy, interference between scanning patterns and interfield organ motion may result in suboptimal dose within target volume. In this study, we developed a simple offline correction technique for uniform scanning proton beam (USPB) delivery to compensate for the interplay between scanning patterns and respiratory motion and demonstrate the effectiveness of our technique in treating liver cancer. METHODS: The computed tomography (CT) and respiration data of two patients who had received stereotactic body radiotherapy for hepatocellular carcinoma were used. In the simulation, the relative beam weight delivered to each respiratory phase is calculated for each beam layer after treatment of each fraction. Respiratory phases with beam weights higher than 50% of the largest weight are considered "skipped phases" for the next fraction. For the following fraction, the beam trigger is regulated to prevent beam layers from starting irradiation in skipped phases by extending the interval between each layer. To calculate dose-volume histogram (DVH), the dose of the target volume at end-exhale (50% phase) was calculated as the sum of each energy layer, with consideration of displacement due to respiratory motion and relative beam weight delivered per respiratory phase. RESULTS: For a single fraction, D1% , D99% , and V100% were 114%, 88%, and 32%, respectively, when 8 Gy/min of dose rate was simulated. Although these parameters were improved with multiple fractions, dosimetric inhomogeneity without motion management remained even at 30 fractions, with V100% 86.9% at 30 fractions. In contrast, the V100% values with adaptation were 96% and 98% at 20 and 30 fractions, respectively. We developed an offline correction technique for USPB therapy to compensate for the interplay effects between respiratory organ motion and USPB beam delivery. CONCLUSIONS: For liver tumor, this adaptive therapy technique showed significant improvement in dose uniformity even with fewer treatment fractions than normal USPB therapy.en_US
dc.identifier.citationAkino, Y., Wu, H., Oh, R. J., & Das, I. J. (). An effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: A case study. Journal of applied clinical medical physics, 20(1), 220–228. doi:10.1002/acm2.12508en_US
dc.identifier.urihttps://hdl.handle.net/1805/19688
dc.language.isoen_USen_US
dc.publisherWileyen_US
dc.relation.isversionof10.1002/acm2.12508en_US
dc.relation.journalJournal of Applied Clinical Medical Physicsen_US
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.sourcePMCen_US
dc.subjectAdaptive therapyen_US
dc.subjectInterplay effectsen_US
dc.subjectProton therapyen_US
dc.subjectRespiratory motionen_US
dc.titleAn effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: A case studyen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ACM2-20-220.pdf
Size:
468.56 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: