Wearable biosensors have the potential to monitor physiological changes associated with opioid overdose among people who use drugs: A proof-of-concept study in a real-world setting

dc.contributor.authorRoth, Alexis M.
dc.contributor.authorTran, Nguyen K.
dc.contributor.authorCocchiaro, Ben
dc.contributor.authorMitchell, Allison K.
dc.contributor.authorSchwartz, David G.
dc.contributor.authorHensel, Devon J.
dc.contributor.authorAtaiants, Janna
dc.contributor.authorBrenner, Jacob
dc.contributor.authorYahav, Inbal
dc.contributor.authorLankenau, Stephen E.
dc.date.accessioned2022-06-29T14:57:50Z
dc.date.available2022-06-29T14:57:50Z
dc.date.issued2021-12-01
dc.description.abstractINTRODUCTION: Wearable biosensors have the potential to monitor physiological change associated with opioid overdose among people who use drugs. METHODS: We enrolled 16 individuals who reported ≥ 4 daily opioid use events within the previous 30 day. Each was assigned a wearable biosensor that measured respiratory rate (RR) and actigraphy every 15 s for 5 days and also completed a daily interview assessing drug use. We describe the volume of RR data collected, how it varied by participant characteristics and drug use over time using repeated measures one-way ANOVA, episodes of acute respiratory depression (≤5 breaths/minute), and self-reported overdose experiences. RESULTS: We captured 1626.4 h of RR data, an average of 21.7 daily hours/participant over follow-up. Individuals with longer injection careers and those engaging in polydrug use captured significantly fewer total hours of respiratory data over follow-up compared to those with shorter injections careers (94.7 vs. 119.9 h, p = 0.04) and injecting fentanyl exclusively (98.7 vs. 119.5 h, p = 0.008), respectively. There were 385 drug use events reported over follow-up. There were no episodes of acute respiratory depression which corresponded with participant reports of overdose experiences. DISCUSSION: Our preliminary findings suggest that using a wearable biosensor to monitor physiological changes associated with opioid use was feasible. However, more sensitive biosensors that facilitate triangulation of multiple physiological data points and larger studies of longer duration are needed.en_US
dc.identifier.citationRoth, A. M., Tran, N. K., Cocchiaro, B., Mitchell, A. K., Schwartz, D. G., Hensel, D. J., Ataiants, J., Brenner, J., Yahav, I., & Lankenau, S. E. (2021). Wearable biosensors have the potential to monitor physiological changes associated with opioid overdose among people who use drugs: A proof-of-concept study in a real-world setting. Drug and Alcohol Dependence, 229(Pt A), 109138. https://doi.org/10.1016/j.drugalcdep.2021.109138en_US
dc.identifier.urihttps://hdl.handle.net/1805/29448
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.isversionof10.1016/j.drugalcdep.2021.109138en_US
dc.subjectAnalgesics, Opioiden_US
dc.subjectBiosensing Techniquesen_US
dc.subjectDrug Overdoseen_US
dc.titleWearable biosensors have the potential to monitor physiological changes associated with opioid overdose among people who use drugs: A proof-of-concept study in a real-world settingen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Roth2021Wearable-AAM.pdf
Size:
582.53 KB
Format:
Adobe Portable Document Format
Description:
Author's Manuscript
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: