Abstract

Introduction: Catheter ablation of atrial fibrillation (AF) currently relies on eliminating triggers, and no reliable method exists to map the arrhythmia itself to identify ablation targets. The aim of this multicenter study was to define the use of Focal Impulse and Rotor Modulation (FIRM) for identifying ablation targets.

Methods: We prospectively enrolled the first (n = 14, 11 males) consecutive patients undergoing FIRM-guided ablation for persistent (n = 11) and paroxysmal AF at 5 centers. A 64-pole basket catheter was used for panoramic right and left atrial mapping during AF. AF electrograms were analyzed using a novel system to identify sustained rotors (spiral waves), or focal beats (centrifugal activation to surrounding atrium). Ablation was performed first at identified sources. The primary endpoints were acute AF termination or organization (>10% cycle length prolongation). Conventional ablation was performed only after FIRM-guided ablation.

Results: Twelve out of 14 cases were mapped. AF sources were demonstrated in all patients (average of 1.9 ± 0.8 per patient). Sources were left atrial in 18 cases, and right atrial in 5 cases, and 21/23 were rotors. FIRM-guided ablation achieved the acute endpoint in all patients, consisting of AF termination in n = 8 (4.9 ± 3.9 minutes at the primary source), and organization in n = 4. Total FIRM time for all patients was 12.3 ± 8.6 minutes.

Conclusions: FIRM-guided ablation revealed localized AF rotors/focal sources in patients with paroxysmal, persistent and longstanding persistent AF. Brief targeted FIRM-guided ablation at a priori identified sites terminated or substantially organized AF in all cases prior to any other ablation.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Shivkumar K, Ellenbogen KA, Hummel JD, Miller JM, Steinberg JS. Acute termination of human atrial fibrillation by identification and catheter ablation of localized rotors and sources: first multicenter experience of focal impulse and rotor modulation (FIRM) ablation. J Cardiovasc Electrophysiol. 2012;23(12):1277-1285. doi:10.1111/jce.12000
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Journal of Cardiovascular Electrophysiology
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}