Abstract

Purpose: To evaluate the performance of a high-dynamic-range quantitative susceptibility mapping (HDR-QSM) cardiac MRI technique to detect intramyocardial hemorrhage (IMH) and quantify iron content using phantom and canine models.

Materials and Methods: A free-running whole-heart HDR-QSM technique for IMH assessment was developed and evaluated in calibrated iron phantoms and 14 IMH female canine models. IMH detection and iron content quantification performance of this technique was compared with the conventional iron imaging approaches, R2*(1/T2*) maps, using measurements from ex vivo imaging as the reference standard.

Results: Phantom studies confirmed HDR-QSM’s accurate iron content quantification and artifact mitigation ability by revealing a strong linear relationship between iron concentration and QSM values (R2, 0.98). In in vivo studies, HDR-QSM showed significantly improved image quality and susceptibility homogeneity in nonaffected myocardium by alleviating motion and off-resonance artifacts (HDR-QSM vs R2*: coefficient of variation, 0.31 ± 0.16 [SD] vs 0.73 ± 0.36 [P < .001]; image quality score [five-point Likert scale:], 3.58 ± 0.75 vs 2.87 ± 0.51 [P < .001]). Comparison between in vivo susceptibility maps and ex vivo measurements showed higher performance of HDR-QSM compared with R2* mapping for IMH detection (area under the receiver operating characteristic curve, 0.96 vs 0.75; P < .001) and iron content quantification (R2, 0.71 vs 0.14).

Conclusion: In a canine model of IMH, the fast and free-running cardiac QSM technique accurately detected IMH and quantified intramyocardial iron content of the entire heart within 5 minutes without requiring breath holding.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Huang Y, Guan X, Zhang X, et al. Accurate Intramyocardial Hemorrhage Assessment with Fast, Free-running, Cardiac Quantitative Susceptibility Mapping. Radiol Cardiothorac Imaging. 2024;6(6):e230376. doi:10.1148/ryct.230376
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Radiology: Cardiothoracic Imaging
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
This item is under embargo {{howLong}}