Piezoresistor-Embedded Multifunctional Magnetic Microactuators for Implantable Self-Clearing Catheter
dc.contributor.author | Yang, Qi | |
dc.contributor.author | Lee, Albert | |
dc.contributor.author | Bentley, R. Timothy | |
dc.contributor.author | Lee, Hyowon | |
dc.contributor.department | Neurological Surgery, School of Medicine | en_US |
dc.date.accessioned | 2020-04-07T18:51:18Z | |
dc.date.available | 2020-04-07T18:51:18Z | |
dc.date.issued | 2019-02-15 | |
dc.description.abstract | Indwelling catheters are used widely in medicine to treat various chronic medical conditions. However, chronic implantation of catheters often leads to a premature failure due to biofilm accumulation. Previously we reported on the development of a self-clearing catheter by integrating polymer-based microscale magnetic actuators. The microactuator provides an active anti-biofouling mechanism to disrupt and remove adsorbed biofilm on demand using an externally applied stimulus. During an in vivo evaluation of self-clearing catheter, we realized that it is important to periodically monitor the performance of implanted microactuators. Here we integrate gold-based piezoresistive strain-gauge on our magnetic microactuators to directly monitor the device deflection with good sensitivity (0.035%/Deg) and linear range (±30°). With the integrated strain-gauge, we demonstrate the multi-functional capabilities of our magnetic microactuators that enable device alignment, flow-rate measurement, and obstruction detection and removal towards the development of chronically implantable self-clearing smart catheter. | en_US |
dc.eprint.version | Author's manuscript | en_US |
dc.identifier.citation | Yang, Q., Lee, A., Bentley, R. T., & Lee, H. (2019). Piezoresistor-Embedded Multifunctional Magnetic Microactuators for Implantable Self-Clearing Catheter. IEEE sensors journal, 19(4), 1373–1378. https://doi.org/10.1109/JSEN.2018.2880576 | en_US |
dc.identifier.uri | https://hdl.handle.net/1805/22496 | |
dc.language.iso | en_US | en_US |
dc.publisher | Institute of Electrical and Electronics Engineers | en_US |
dc.relation.isversionof | 10.1109/JSEN.2018.2880576 | en_US |
dc.relation.journal | IEEE Sensors Journal | en_US |
dc.rights | Publisher Policy | en_US |
dc.source | PMC | en_US |
dc.subject | Piezoresistive sensor | en_US |
dc.subject | Biofouling | en_US |
dc.subject | Implantable device | en_US |
dc.subject | Magnetic microactuators | en_US |
dc.subject | Strain gauge | en_US |
dc.title | Piezoresistor-Embedded Multifunctional Magnetic Microactuators for Implantable Self-Clearing Catheter | en_US |
dc.type | Article | en_US |