A Novel Fluorescent Clinical Method to Rapidly Quantify Plasma Volume

dc.contributor.authorMolitoris, Bruce A.
dc.contributor.authorGeorge, Anthony G.
dc.contributor.authorMurray, Patrick T.
dc.contributor.authorMeier, Daniel
dc.contributor.authorReilly, Erinn S.
dc.contributor.authorBarreto, Erin
dc.contributor.authorSandoval, Ruben M.
dc.contributor.authorRizk, Dana V.
dc.contributor.authorShaw, Andrew D.
dc.contributor.authorPeacock, W. Frank
dc.contributor.departmentMedicine, School of Medicineen_US
dc.date.accessioned2020-06-22T19:06:37Z
dc.date.available2020-06-22T19:06:37Z
dc.date.issued2019
dc.description.abstractObjectives To determine the performance of a rapid fluorescent indicator technique for measuring plasma volume (PV). Methods This was an open-label, observational evaluation of a two-component intravenous visible fluorescent dye technique to rapidly measure PV in 16 healthy subjects and 16 subjects with chronic kidney disease (8 stage 3 and 8 stage 4 CKD), at 2 clinical research sites. The method consisted of a single intravenous injection of 12 mg of a large 150-kDa carboxy-methyl dextran conjugated to a fluorescent rhodamine-derived dye as the PV marker (PVM), and 35 mg of a small 5-kDa carboxy-methyl dextran conjugated to fluorescein, the renal clearance marker. Dye concentrations were quantified 15 min after the injections for initial PV measurements using the indicator-dilution principle. Additional samples were taken over 8 h to evaluate the stability of the PVM as a determinant of PV. Blood volumes (BV) were calculated based on PV and the subject’s hematocrit. Pharmacokinetic parameters were calculated from the plasma concentration data taken over several days using noncompartmental methods (Phoenix WinNonlin®). Linear correlation and Bland-Altman plots were used to compare visible fluorescent injectate-measured PV compared to Nadler’s formula for estimating PV. Finally, 8 healthy subjects received 350 mL infusion of a 5% albumin solution in normal saline over 30 min and a repeat PV determination was then carried out. Results PV and BV varied according to weight and body surface area, with PV ranging from 2,115 to 6,234 mL and 28.6 to 41.9 mL/kg when weight adjusted. Both parameters were stable for > 6 h with repeated plasma measurements of the PVM. There was no difference between healthy subjects and CKD subjects. Overall, there was general agreement with Nadler’s estimation formula for the mean PV in subjects. A 24-h repeat dose measurement in 8 healthy subjects showed PV variability of 98 ± 121 mL (mean = 3.8%). Additionally, following an intravenous bolus of 350 mL of a 5% albumin solution in normal saline in 8 healthy subjects, the mean (SD) measured increase in PV was 356 (±50.0) mL post-infusion. There were no serious adverse events reported during the study. Conclusions This minimally invasive fluorescent dye approach safely allowed for rapid, accurate, and reproducible determination of PV, BV, and dynamic monitoring of changes following fluid administration.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationMolitoris, B. A., George, A. G., Murray, P. T., Meier, D., Reilly, E. S., Barreto, E., Sandoval, R. M., Rizk, D. V., Shaw, A. D., & Peacock, W. F. (2019). A Novel Fluorescent Clinical Method to Rapidly Quantify Plasma Volume. Cardiorenal medicine, 9(3), 168–179. https://doi.org/10.1159/000496480en_US
dc.identifier.urihttps://hdl.handle.net/1805/23040
dc.language.isoen_USen_US
dc.publisherKarger Publishersen_US
dc.relation.isversionof10.1159/000496480en_US
dc.relation.journalCardiorenal Medicineen_US
dc.rightsPublisher Policyen_US
dc.sourcePMCen_US
dc.subjectCarboxy-methyl dextranen_US
dc.subjectBlood volumeen_US
dc.subjectChronic kidney diseaseen_US
dc.subjectFluorescent indicator techniqueen_US
dc.titleA Novel Fluorescent Clinical Method to Rapidly Quantify Plasma Volumeen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
nihms-1562781.pdf
Size:
1023.3 KB
Format:
Adobe Portable Document Format
Description:
Main article