A Multicenter Clinical Study To Demonstrate the Diagnostic Accuracy of the GenMark Dx ePlex Blood Culture Identification Gram-Negative Panel

Date
2021
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
American Society for Microbiology
Abstract

Bacteremia can progress to septic shock and death without appropriate medical intervention. Increasing evidence supports the role of molecular diagnostic panels in reducing the clinical impact of these infections through rapid identification of the infecting organism and associated antimicrobial resistance genes. We report the results of a multicenter clinical study assessing the performance of the GenMark Dx ePlex investigational-use-only blood culture identification Gram-negative panel (BCID-GN), a rapid diagnostic assay for detection of bloodstream pathogens in positive blood culture (PBC) bottles. Prospective, retrospective, and contrived samples were tested. Results from the BCID-GN were compared to standard-of-care bacterial identification methods. Antimicrobial resistance genes (ARGs) were identified using PCR and sequence analysis. The final BCID-GN analysis included 2,444 PBC samples, of which 926 were clinical samples with negative Gram stain results. Of these, 109 samples had false-negative and/or -positive results, resulting in an overall sample accuracy of 88.2% (817/926). After discordant resolution, overall sample accuracy increased to 92.9% (860/926). Pre- and postdiscordant resolution sample accuracy excludes 37 Gram-negative organisms representing 20 uncommon genera, 10 Gram-positive organisms, and 1 Candida species present in 5% of samples that are not targeted by the BCID-GN. The overall weighted positive percent agreement (PPA), which averages the individual PPAs from the 27 targets (Gram-negative and ARG), was 94.9%. The limit of detection ranged from 104 to 107 CFU/ml, except for one strain of Fusobacterium necrophorum at 108 CFU/ml.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Wolk DM, Young S, Whitfield NN, et al. A Multicenter Clinical Study To Demonstrate the Diagnostic Accuracy of the GenMark Dx ePlex Blood Culture Identification Gram-Negative Panel. J Clin Microbiol. 2021;59(9):e0248420. doi:10.1128/JCM.02484-20
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Journal of Clinical Microbiology
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}