IVUS Validation of Patient Coronary Artery Lumen Area Obtained from CT Images

dc.contributor.authorLuo, Tong
dc.contributor.authorWischgoll, Thomas
dc.contributor.authorKoo, Bon Kwon
dc.contributor.authorHuo, Yunlong
dc.contributor.authorKassab, Ghassan S.
dc.contributor.departmentSurgery, School of Medicine
dc.date.accessioned2025-04-23T11:21:33Z
dc.date.available2025-04-23T11:21:33Z
dc.date.issued2014-01-29
dc.description.abstractAims: Accurate computed tomography (CT)-based reconstruction of coronary morphometry (diameters, length, bifurcation angles) is important for construction of patient-specific models to aid diagnosis and therapy. The objective of this study is to validate the accuracy of patient coronary artery lumen area obtained from CT images based on intravascular ultrasound (IVUS). Methods and results: Morphometric data of 5 patient CT scans with 11 arteries from IVUS were reconstructed including the lumen cross sectional area (CSA), diameter and length. The volumetric data from CT images were analyzed at sub-pixel accuracy to obtain accurate vessel center lines and CSA. A new center line extraction approach was used where an initial estimated skeleton in discrete value was obtained using a traditional thinning algorithm. The CSA was determined directly without any circular shape assumptions to provide accurate reconstruction of stenosis. The root-mean-square error (RMSE) for CSA and diameter were 16.2% and 9.5% respectively. Conclusions: The image segmentation and CSA extraction algorithm for reconstruction of coronary arteries proved to be accurate for determination of vessel lumen area. This approach provides fundamental morphometric data for patient-specific models to diagnose and treat coronary artery disease.
dc.eprint.versionFinal published version
dc.identifier.citationLuo T, Wischgoll T, Kwon Koo B, Huo Y, Kassab GS. IVUS validation of patient coronary artery lumen area obtained from CT images. PLoS One. 2014;9(1):e86949. Published 2014 Jan 29. doi:10.1371/journal.pone.0086949
dc.identifier.urihttps://hdl.handle.net/1805/47374
dc.language.isoen_US
dc.publisherPublic Library of Science
dc.relation.isversionof10.1371/journal.pone.0086949
dc.relation.journalPLoS One
dc.rightsAttribution 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourcePMC
dc.subjectCoronary artery disease
dc.subjectCoronary vessels
dc.subjectInterventional ultrasonography
dc.titleIVUS Validation of Patient Coronary Artery Lumen Area Obtained from CT Images
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Luo2014Validation-CCBY.pdf
Size:
747.55 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.04 KB
Format:
Item-specific license agreed upon to submission
Description: