Comparing adenoma and polyp miss rates for total underwater colonoscopy versus standard CO2: a randomized controlled trial using a tandem colonoscopy approach

Date
2018
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

Background and Aims Although water exchange may improve adenoma detection when compared to CO2, it is unclear whether water is a better medium to fill the lumen during withdrawal and visualize the mucosa. Total underwater (TUC) involves the use of water exchange with the air valve off during insertion followed by the inspection of the mucosa under water. Our goal was to use a tandem colonoscopy design to compare miss rates for TUC to standard CO2 for polyps and adenomas.

Methods We randomized participants (NCT03231917; clinicaltrials.gov) to undergo tandem colonoscopies using TUC or CO2 first. In TUC, water exchange was performed during insertion and withdrawal was performed under water. For the CO2 colonoscopy both insertion and withdrawal were performed with CO2. The main outcomes were miss rates for polyps and adenomas for the first examination calculated as the number of additional polyps/adenomas detected during the second examination divided by the total number of polyps/adenomas detected for both examinations. Inspection times were calculated by subtracting time for polypectomy and care was given to keep the times equal for both examinations.

Results A total of 121 participants were randomized with 61 having CO2 first. The overall miss rate for polyps was higher for the TUC first group (81/237; 34%) as compared to the CO2 first cohort (57/264; 22%)(p=0.002). In addition, the overall miss rate for all adenomas was higher for the TUC first group (52/146; 36%) as compared with the CO2 group (37/159; 23%) (p=0.025). However, 1 of the 3 endoscopists had higher polyp/adenoma miss rates for CO2 but these were not statistically significant differences. The insertion time was longer for TUC than CO2. After adjusting for times, participant characteristics and bowel preparation, the miss rate for polyps was higher for TUC than CO2.

Conclusions We found that TUC had an overall higher polyp and adenoma miss rate than colonoscopy performed with CO2, and TUC took longer to perform. However, TUC may benefit some endoscopists, an issue that requires further study.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Anderson, J. C., Kahi, C. J., Sullivan, A., MacPhail, M., Garcia, J., & Rex, D. K. (2018). Comparing adenoma and polyp miss rates for total underwater colonoscopy versus standard CO2: a randomized controlled trial using a tandem colonoscopy approach. Gastrointestinal Endoscopy. https://doi.org/10.1016/j.gie.2018.09.046
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Gastrointestinal Endoscopy
Rights
Publisher Policy
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}