Abstract

Background: Accurate and timely methods for the diagnosis of histoplasmosis in endemic resource-limited settings are largely lacking. Histoplasma galactomannan antigen detection by enzyme immunoassay (EIA) is the most widely used method for the diagnosis of acute pulmonary and disseminated histoplasmosis in the United States (USA). EIA methods have constraints in resource-limited settings including cost, turnaround time, and the need for large reference laboratories, leading to missed or delayed diagnoses and poor outcomes. Lateral flow assays (LFA) are practical methods that can be used in this setting for Histoplasma antigen detection.

Methods: Frozen urine specimens were submitted to MiraVista (MVista) for Histoplasma antigen EIA testing from three academic medical centers in highly endemic areas of the USA. They were also blinded and tested for the MVista Histoplasma LFA by skilled MVista technologists. Medical records were reviewed for clinical information. Patients were classified as controls or cases of histoplasmosis. Cases were divided into proven or probable, pulmonary, or disseminated, immune competent or immune suppressed, and mild, moderate, or severe.

Results: 352 subjects were enrolled, including 66 cases of histoplasmosis (44 proven, 22 probable) and 286 controls. Most of the cases were immunocompromised (68%). 76% had disseminated histoplasmosis. 6% were mild, 66% moderate, and 28% severe. A high degree of concordance was found between LFA and EIA results (kappa 0.837, OR 372.7, LR 204, p< 0.001). Overall, the sensitivity and specificity of the LFA were 78.8% and 99.3% respectively (kappa 0.84, p< 0.001). The sensitivity was higher in proven cases (93.2%), in patient with disseminated (94.7%), moderate (80%) and severe disease (94%), and those with galactomannan levels ≥ 2 ng/mL (97.7%). Specificity was 99.3% in proven cases, 99.3% in patient with moderate and severe disease, and 96.4% in those with galactomannan levels ≥ 2 ng/mL.

Conclusion: The MVista Histoplasma galactomannan LFA may meet the need for accurate rapid diagnosis of histoplasmosis in resource-limited settings, especially in patients with relatively high disease burden, potentially reducing morbidity and mortality.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
1. Abdallah W, Myint T, LaRue RW, et al. 721. Diagnosis of Histoplasmosis Using the MVista Histoplasma Galactomannan Antigen Qualitative Lateral Flow-Based Immunoassay; A Multicenter Study. Open Forum Infectious Diseases. 2021;8(Supplement_1):S459-S460. doi:10.1093/ofid/ofab466.918
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Open Forum Infectious Diseases
Source
Publisher
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}