Impact of water filling on terminal ileum intubation with a distal-tip mucosal exposure device

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2019
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

Background and Aims Endocuff improves detection at colonoscopy but seems to impede terminal ileal (TI) intubation. We assessed the impact of Endocuff Vision (EV) on TI intubation using adult or pediatric colonoscopes and evaluated whether filling the cecum with gas versus water affected the impact of EV on TI intubation.

Methods Using a prospectively recorded quality control database, we explored the impact of EV on TI intubation in ≤1 minute. We used adult and pediatric colonoscopes and tested the effect of filling the cecum with gas versus water. If the initial attempt failed, then the alternative (water vs gas) was tried as a rescue method.

Results TI intubation in ≤1 minute occurred in 91% of colonoscopies without EV versus 65% with EV, but the use of the pediatric colonoscope with EV had a higher success rate for TI intubation in ≤1 minute compared with the adult colonoscope with EV (73% vs 57%, P = .043). TI intubation in ≤1 minute was more successful with EV when the cecum was filled with water rather than gas (74% vs 56%, P = .019), but the benefit of water filling was limited to the adult colonoscope with EV. When EV was in place, water filling was more successful as a rescue method of TI intubation (58% vs 21%, P = .011).

Conclusions EV adversely affects TI intubation, particularly for adult colonoscopes. Water filling of the cecum mitigates the impact of EV on TI intubation with adult colonoscopes.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Vemulapalli, K. C., Tippins, N., Lahr, R. E., Sullivan, A. W., Love, E., McWhinney, C. D., … Rex, D. K. (2019). Impact of water filling on terminal ileum intubation with a distal-tip mucosal exposure device. Gastrointestinal Endoscopy. https://doi.org/10.1016/j.gie.2019.11.016
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Gastrointestinal Endoscopy
Source
Publisher
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}