EFFECTS OF ORTHODONTIC MINI-IMPLANT DIAMETER ON MICRODAMAGE.

dc.contributor.authorCruz, Enrique
dc.contributor.authorLiu, Sean
dc.contributor.authorSun, Jun
dc.contributor.authorBlanchard, Steven B.
dc.contributor.authorSoto, Armando
dc.contributor.authorStewart, Kelton T.
dc.contributor.authorAllen, Matthew R.
dc.contributor.authorLiu, Sean
dc.date.accessioned2015-11-24T18:06:00Z
dc.date.available2015-11-24T18:06:00Z
dc.date.issued2012-04-13
dc.descriptionPOSTER ABSTRACTen_US
dc.description.abstractMicrodamage reduces bone mechanical properties and thus could possi-bly contribute to implant failure. The objective of this study was to investi-gate whether the diameter of mini-implants (MI) affects microdamage gen-eration and whether this differs between the mandible and maxilla due to their contrasting cortical thicknesses. Methods: Maxillary and mandibular quadrants of 5 dogs were randomly assigned to receive, in situ, no interven-tion (control), pilot drilling only, or pilot drilling plus one of three diameters of MI: 1.4 (n=18), 1.6 (n=18), and 2.0 mm (n=18). Microdamage was as-sessed on basic fuchsin stained sections using epifluorescence microscopy. Results: No microdamage was found in the non-drilling controls. Pilot drill-ing produced only minimal microdamage in the maxilla but more microdamage in the mandible. There was significantly higher microdamage generated in the mandible, compared to the maxilla (p<0.05). In the maxil-la, although insertion of all implants produced higher microdamage than the control and pilot drilling, there were no differences between the 3 MI diame-ters. In the mandible, insertion of implants generated significantly higher microdamage than the control, but it did not produce higher microdamage than pilot drilling. Similarly, no differences in microdamage were found be-tween 3 MI diameters. Conclusion: Insertion of MIs in the mandible pro-duced higher microdamage than in the maxilla, which may explain that the higher MI failure rate in the mandible. Implant diameter did not affect over-all microdamage burden in either jaw. Microdamage was mostly generated by pilot drilling through the cortex in the mandible, while microdamage in the maxilla was mainly produced when manual inserting MIs after pilot drill-ing.en_US
dc.identifier.citationEnrique Cruz, Sean Liu, Jun Sun, Steven B. Blanchard, Armando Soto, Kelton T Stewart, Matthew R. Allen and Sean Liu. (2012, April 13). EFFECTS OF ORTHODONTIC MINI-IMPLANT DIAMETER ON MICRODAMAGE. Poster session presented at IUPUI Research Day 2012, Indianapolis, Indiana.en_US
dc.identifier.urihttps://hdl.handle.net/1805/7541
dc.language.isoen_USen_US
dc.publisherOffice of the Vice Chancellor for Researchen_US
dc.subjectmini-implants (MI)en_US
dc.subjectMicrodamageen_US
dc.subjectmaxillaen_US
dc.subjectmandibleen_US
dc.titleEFFECTS OF ORTHODONTIC MINI-IMPLANT DIAMETER ON MICRODAMAGE.en_US
dc.typePosteren_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Cruz-Effect.pdf
Size:
11.83 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: