EFFECTS OF ORTHODONTIC MINI-IMPLANT DIAMETER ON MICRODAMAGE.

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2012-04-13
Language
American English
Embargo Lift Date
Department
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Office of the Vice Chancellor for Research
Abstract

Microdamage reduces bone mechanical properties and thus could possi-bly contribute to implant failure. The objective of this study was to investi-gate whether the diameter of mini-implants (MI) affects microdamage gen-eration and whether this differs between the mandible and maxilla due to their contrasting cortical thicknesses. Methods: Maxillary and mandibular quadrants of 5 dogs were randomly assigned to receive, in situ, no interven-tion (control), pilot drilling only, or pilot drilling plus one of three diameters of MI: 1.4 (n=18), 1.6 (n=18), and 2.0 mm (n=18). Microdamage was as-sessed on basic fuchsin stained sections using epifluorescence microscopy. Results: No microdamage was found in the non-drilling controls. Pilot drill-ing produced only minimal microdamage in the maxilla but more microdamage in the mandible. There was significantly higher microdamage generated in the mandible, compared to the maxilla (p<0.05). In the maxil-la, although insertion of all implants produced higher microdamage than the control and pilot drilling, there were no differences between the 3 MI diame-ters. In the mandible, insertion of implants generated significantly higher microdamage than the control, but it did not produce higher microdamage than pilot drilling. Similarly, no differences in microdamage were found be-tween 3 MI diameters. Conclusion: Insertion of MIs in the mandible pro-duced higher microdamage than in the maxilla, which may explain that the higher MI failure rate in the mandible. Implant diameter did not affect over-all microdamage burden in either jaw. Microdamage was mostly generated by pilot drilling through the cortex in the mandible, while microdamage in the maxilla was mainly produced when manual inserting MIs after pilot drill-ing.

Description
POSTER ABSTRACT
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Enrique Cruz, Sean Liu, Jun Sun, Steven B. Blanchard, Armando Soto, Kelton T Stewart, Matthew R. Allen and Sean Liu. (2012, April 13). EFFECTS OF ORTHODONTIC MINI-IMPLANT DIAMETER ON MICRODAMAGE. Poster session presented at IUPUI Research Day 2012, Indianapolis, Indiana.
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Source
Alternative Title
Type
Poster
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Full Text Available at
This item is under embargo {{howLong}}