Investigation of Energy Efficient Retrofit HVAC Systems for a University: Case Study

dc.contributor.authorLigade, Jayraj
dc.contributor.authorRazban, Ali
dc.contributor.departmentMechanical and Energy Engineering, School of Engineering and Technologyen_US
dc.date.accessioned2020-09-11T17:10:11Z
dc.date.available2020-09-11T17:10:11Z
dc.date.issued2019-10
dc.description.abstractWe did energy efficient retrofits for the Indiana University Purdue University—Indianapolis Health Science Building using the eQuest energy software. The current dual-fan dual-duct (DFDD) system is 41 years old and has a higher energy utilization index (EUI) than the national average for similar building types. The baseline model with the DFDD system was compared with the actual electrical consumption. Then, two energy efficiency measures (EEMs) were applied to the model. The first EEM was ‘DFDD system with chilled water and steam heating,’ and the second EEM was ‘single-duct variable air volume (VAV) with chilled water and electric reheat.’ After comparative simulations and analyses, it was determined that the ‘single duct VAV with chilled water and electric reheat’ was the most energy efficient and saved 28% in utility costs. The recommendation given to the facility services was to change the current DFDD system to the single-duct VAV system. The single-duct VAV system will save energy and create additional space above the ceiling after the heating duct is removed.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationLigade, J., & Razban, A. (2019). Investigation of Energy Efficient Retrofit HVAC Systems for a University: Case Study. Sustainability, 11(20), 5593. https://doi.org/10.3390/su11205593en_US
dc.identifier.urihttps://hdl.handle.net/1805/23798
dc.language.isoenen_US
dc.publisherMDPIen_US
dc.relation.isversionof10.3390/su11205593en_US
dc.relation.journalSustainabilityen_US
dc.rightsAttribution 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0*
dc.sourcePublisheren_US
dc.subjectenergy efficient HVAC retrofiten_US
dc.subjecteQuesten_US
dc.subjectsimulationen_US
dc.titleInvestigation of Energy Efficient Retrofit HVAC Systems for a University: Case Studyen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ligade2019Investigation.pdf
Size:
897.42 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: