Life-threatening post-thrombectomy hypotension due to residual complications from a translumbar catheter
dc.contributor.author | Friedman, Allon N. | |
dc.contributor.author | Butty, Sabah D. | |
dc.contributor.department | Department of Medicine, IU School of Medicine | en_US |
dc.date.accessioned | 2016-03-18T16:12:47Z | |
dc.date.available | 2016-03-18T16:12:47Z | |
dc.date.issued | 2010-10 | |
dc.description.abstract | Translumbar catheters offer an alternative life-saving option in patients without conventional dialysis access, though their use and complication rates are poorly understood. We report the first case in the medical literature of a translumbar catheter inducing a central venous stenosis. This occult sequela converted what is usually a subclinical complication from an arteriovenous graft thrombectomy into a life-threatening one. This unusual clinical presentation highlights the need for clinicians to recognize the potential serious implications of translumbar catheter-induced occult central venous stenosis. | en_US |
dc.eprint.version | Final published version | en_US |
dc.identifier.citation | Friedman, A. N., & Butty, S. D. (2010). Life-threatening post-thrombectomy hypotension due to residual complications from a translumbar catheter. NDT Plus, 3(5), 465–467. http://doi.org/10.1093/ndtplus/sfq112 | en_US |
dc.identifier.issn | 1753-0784 | en_US |
dc.identifier.uri | https://hdl.handle.net/1805/8927 | |
dc.language.iso | en_US | en_US |
dc.publisher | Oxford University Press | en_US |
dc.relation.isversionof | 10.1093/ndtplus/sfq112 | en_US |
dc.relation.journal | NDT Plus | en_US |
dc.rights | Attribution-NonCommercial 3.0 United States | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/3.0/us/ | |
dc.source | Publisher | en_US |
dc.subject | arteriovenous graft | en_US |
dc.subject | stenosis | en_US |
dc.subject | thrombectomy | en_US |
dc.subject | translumbar catheter | en_US |
dc.title | Life-threatening post-thrombectomy hypotension due to residual complications from a translumbar catheter | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- NDT Plus-2010-Friedman-465-7.pdf
- Size:
- 1.82 MB
- Format:
- Adobe Portable Document Format
- Description:
- Final published version
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.88 KB
- Format:
- Item-specific license agreed upon to submission
- Description: