Polypropylene Mesh Predicts Mesh/Suture Exposure After Sacrocolpopexy Independent of Known Risk Factors
Date
Language
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Abstract
Objective(s) The aim of this study was to determine if ultralightweight polypropylene mesh reduced the risk of mesh/suture exposure after sacrocolpopexy compared with heavier-weighted polypropylene.
Methods Bivariate and multivariate analyses were used to interpret data from 133 cases and 261 control subjects to evaluate independent predictors of mesh/suture exposure after sacrocolpopexy from 2003 to 2013.
Results Multivariate logistic regression revealed that prior surgery for incontinence (odds ratio [OR], 2.87; 95% confidence interval [CI], 1.19–6.96), porcine acellular cross-linked collagen matrix with medium-weight polypropylene mesh (OR, 4.95; 95% CI, 1.70–14.42), other polypropylene mesh (OR, 6.73; 95% CI, 1.12–40.63), nonabsorbable braided suture for vaginal mesh attachment (OR, 4.52; 95% CI, 1.53–15.37), and immediate perioperative complications (OR, 3.64; 95% CI, 1.53–13.37) were independent risk factors for mesh/suture exposure. After multivariate analysis, ultralightweight polypropylene mesh was no longer associated with decreased rates of mesh/suture exposure after controlling for known risk factors identified during bivariate analysis (P = 0.423).
Conclusions Both mesh choice and suture selection remained independent predictors of mesh/suture exposure, with heavier meshes increasing and monofilament suture decreasing rates of mesh/suture exposure. Based on this study, surgeons may consider use of delayed-absorbable, monofilament suture over nonabsorbable braided suture for attachment of vaginal mesh to reduce the risk of mesh/suture exposure when using mesh.