A Usability Comparison of Laser Suction Handpieces for Percutaneous Nephrolithotomy

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2016
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Liebert
Abstract

Introduction: The holmium laser has revolutionized the practice of minimally invasive endoscopy for kidney stones. Recently, a novel, rigid handpiece for use in percutaneous nephrolithotomy (PCNL) that couples the holmium laser with suction has been developed. To date, limited data exist regarding the usability and ergonomics of such treatment systems. We thus sought to compare surgeon-rated usability with three different suction laser handpieces in a porcine model.

Materials and Methods: We performed bilateral reverse PCNL on four female domestic farm pigs. After induction of general anesthesia, percutaneous access was obtained into each kidney by using biplanar fluoroscopy and 8 mm stones (plaster of Paris) were inserted into the calix or renal pelvis for treatment. Four surgeons tested the LASER Suction Tube (Karl Storz®, Germany), LithAssist™ (Cook® Medical), and Suction Handpiece (HP) (Lumenis®, Israel) by using a combination of fragmentation (5 Joules/20 Hertz) and dusting (0.8 Joules/80 Hertz) settings on the Lumenis pulse 120 H laser. The primary outcome assessed was the ease of use of the three devices as measured by a surgeon questionnaire.

Results: A total of 15 stones were treated in 8 renal units. The mean time required for stone fragmentation was 8 min. The mean handling and suction efficiency scores were similar between devices. The Suction HP offered the best laser fiber visibility during lithotripsy.

Conclusion: Suction laser handpieces offer an option to treat renal stones via PCNL, with limited differences noted in most surgeon ratings between devices.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Dauw, C. A., Borofsky, M. S., York, N., & Lingeman, J. E. (2016). A Usability Comparison of Laser Suction Handpieces for Percutaneous Nephrolithotomy. Journal of endourology, 30(11), 1165-1168. https://doi.org/10.1089/end.2016.0203
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Journal of Endourology
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}