Reliability and Validity of the OrthoMechanics Sequential Analyzer

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2014-04-11
Language
American English
Embargo Lift Date
Department
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Office of the Vice Chancellor for Research
Abstract

Purpose: The aim of this study was to evaluate the reliability and validity of newly developed software in the assessment of orthodontic tooth movement three dimensionally. Methods: The sample consisted of pre- and post- treatment computed tomography scans and plaster dental models of 20 orthodontic subjects treated with a hyrax expander as a part of their comprehensive orthodontic treatment. Dental arch measurements, including arch widths, tooth inclinations and angulations, were measured on the scans using InvivoDental 3D imaging software version 5.1. The plaster dental models were laser scanned, superimposed, and measurements were obtained digitally using the new software. Agreement between the digital models and the CT measurements was evaluated using intraclass correlation coefficients (ICCs), paired t-tests, and Bland-Altman plots. A p-value of ≤ 0.05 was considered statistically significant. Results: High agreement (ICC > 0.9), a non-significant paired t-test, and no indication of agreement discrepancies were observed for most of the measured parameters. Conclusions: The new software program offers a valid and reliable tool concerning dental arch measurements obtained from 3D laser scanned models. It could be considered a possible practical method that helps the orthodontist evaluate the treatment progress in a non-invasive manner and without unnecessary radiation exposure. Funding: Indiana University Purdue University - Office of the Vice Chancellor for Research & the Funding Opportunities for Research Commercialization and Economics Success (FORCES).

Description
poster abstract
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Ghomeima, A., Talaat, S., Kaboudan, A., Kula, K. (2014, April 11). Reliability and Validity of the OrthoMechanics Sequential Analyzer. Poster session presented at IUPUI Research Day 2014, Indianapolis, Indiana.
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Source
Alternative Title
Type
Other
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Full Text Available at
This item is under embargo {{howLong}}