Objective metric of energy absorbed in tibial plateau fractures corresponds well to clinician assessment of fracture severity

Date
2016-10
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Wolters Kluwer
Abstract

Objectives Determine the agreement between subjective assessments of fracture severity and an objective CT-based metric of fracture energy in tibial plateau fractures.

Methods Six fellowship-trained orthopaedic trauma surgeons independently rank-ordered 20 tibial plateau fractures in terms of severity based upon AP and lateral knee radiographs. A CT-based image analysis methodology was used to quantify the fracture energy, and agreement between the surgeons’ severity rankings and the fracture energy metric was tested by computing their concordance, a statistical measure that estimates the probability that any two cases would be ranked with the same ordering by two different raters or methods.

Results Concordance between the six orthopaedic surgeons ranged from 82% to 93%, and concordance between surgeon severity rankings and the computed fracture energy ranged from 73% to 78%.

Conclusions There is a high level of agreement between experienced surgeons in their assessments of tibial plateau fracture severity, and a slightly lower agreement between the surgeon assessments and an objective CT-based metric of fracture energy. Taken together, these results suggest that experienced surgeons share a similar understanding of what makes a tibial plateau fracture more or less severe, and an objective CT-based metric of fracture energy captures much but not all of that information. Further research is ongoing to characterize the relationship between surgeon assessments of severity, fracture energy, and the eventual clinical outcomes for patients with fractures of the tibial plateau.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Kempton, L. B., Dibbern, K., Anderson, D. D., Morshed, S., Higgins, T. F., Marsh, J. L., & McKinley, T. O. (2016). Objective metric of energy absorbed in tibial plateau fractures corresponds well to clinician assessment of fracture severity. Journal of Orthopaedic Trauma, 30(10), 551–556. https://doi.org/10.1097/BOT.0000000000000636
ISSN
0890-5339
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Journal of orthopaedic trauma
Rights
Publisher Policy
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}