The Effects on Technologist Occupational Exposure in PET/CT Departments When Working with Students at Various Levels of Supervision

Date
2020-09
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
SNM
Abstract

The purpose of this study was to evaluate the effect that the presence of a student in the PET/CT department has on the technologist’s occupational radiation exposure and whether this effect is influenced by the type of supervision performed. Methods: This was a retrospective, institutional review board–approved study that collected data from 2 PET/CT departments. Dosimetry reports, correlated with the clinical schedules of the students, were normalized for workflow (amount of radioactivity), the number of technologists, and the number of monitored days in the department. A 2-sample t test assuming unequal variance with an α of 0.05 was used to compare doses between with-student and without-student groups and between direct-supervision and indirect-supervision groups. Results: The study consisted of a dataset of 42 dosimetry reports, 19 with students and 23 without students. When comparing with-student and without-student groups, the total (n = 42) extremity dose had a P value of 0.012 with a mean of 0.0011665 μSv/MBq/technologist/d; all other dose comparisons between groups were greater than 0.05 (P > 0.05). For indirect supervision (n = 21), the extremity-dose P value was 0.298. The other dose P values were all less than 0.05. For direct supervision (n = 21), the dose P values were all greater than 0.05. There was a trend toward decreasing exposure of technologists when students were in the department. Conclusion: Extremity dose decreases when students are present. There is a trend toward decreasing dose with indirect supervision.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Farkas, J., Martin, M., Nielsen, C., & Jennings, S. G. (2020). The Effects on Technologist Occupational Exposure in PET/CT Departments When Working with Students at Various Levels of Supervision. Journal of Nuclear Medicine Technology, 48(3), 214–217. https://doi.org/10.2967/jnmt.119.241398
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Journal of Nuclear Medicine Technology
Rights
Publisher Policy
Source
Publisher
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}