Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software

dc.contributor.authorHo, Chang Y.
dc.contributor.authorHussain, Sajjad
dc.contributor.authorAlam, Tariq
dc.contributor.authorAhmad, Iftikhar
dc.contributor.authorWu, Isaac C.
dc.contributor.authorO’Neill, Darren P.
dc.contributor.departmentRadiology and Imaging Sciences, School of Medicine
dc.date.accessioned2025-05-28T07:29:25Z
dc.date.available2025-05-28T07:29:25Z
dc.date.issued2013
dc.description.abstractThis study aims to assess the diagnostic accuracy of a single vendor commercially available CT perfusion (CTP) software in predicting stroke. A retrospective analysis on patients presenting with stroke-like symptoms within 6 h with CTP and diffusion-weighted imaging (DWI) was performed. Lesion maps, which overlays areas of computer-detected abnormally elevated mean transit time (MTT) and decreased cerebral blood volume (CBV), were assessed from a commercially available software package and compared to qualitative interpretation of color maps. Using DWI as the gold standard, parameters of diagnostic accuracy were calculated. Point biserial correlation was performed to assess for relationship of lesion size to a true positive result. Sixty-five patients (41 females and 24 males, age range 22-92 years, mean 57) were included in the study. Twenty-two (34 %) had infarcts on DWI. Sensitivity (83 vs. 70 %), specificity (21 vs. 69 %), negative predictive value (77 vs. 84 %), and positive predictive value (29 vs. 50 %) for lesion maps were contrasted to qualitative interpretation of perfusion color maps, respectively. By using the lesion maps to exclude lesions detected qualitatively on color maps, specificity improved (80 %). Point biserial correlation for computer-generated lesions (R pb = 0.46, p < 0.0001) and lesions detected qualitatively (R pb = 0.32, p = 0.0016) demonstrated positive correlation between size and infarction. Seventy-three percent (p = 0.018) of lesions which demonstrated an increasing size from CBV, cerebral blood flow, to MTT/time to peak were true positive. Used in isolation, computer-generated lesion maps in CTP provide limited diagnostic utility in predicting infarct, due to their inherently low specificity. However, when used in conjunction with qualitative perfusion color map assessment, the lesion maps can help improve specificity.
dc.eprint.versionFinal published version
dc.identifier.citationHo CY, Hussain S, Alam T, Ahmad I, Wu IC, O'Neill DP. Accuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software. Emerg Radiol. 2013;20(3):203-212. doi:10.1007/s10140-012-1102-8
dc.identifier.urihttps://hdl.handle.net/1805/48416
dc.language.isoen_US
dc.publisherSpringer
dc.relation.isversionof10.1007/s10140-012-1102-8
dc.relation.journalEmergency Radiology
dc.rightsAttribution 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourcePMC
dc.subjectCT perfusion
dc.subjectStroke
dc.subjectDiagnostic accuracy
dc.subjectCT perfusion software
dc.titleAccuracy of CT cerebral perfusion in predicting infarct in the emergency department: lesion characterization on CT perfusion based on commercially available software
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ho2013Accuracy-CCBY.pdf
Size:
574.47 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.04 KB
Format:
Item-specific license agreed upon to submission
Description: