PIE-FLIM Measurements of Two Different FRETBased Biosensor Activities in the Same Living Cells

dc.contributor.authorReissaus, Christopher A.
dc.contributor.authorDay, Kathleen H.
dc.contributor.authorMirmira, Raghavendra G.
dc.contributor.authorDunn, Kenneth W.
dc.contributor.authorPavalko, Fredrick M.
dc.contributor.authorDay, Richard N.
dc.contributor.departmentPediatrics, School of Medicineen_US
dc.date.accessioned2022-08-02T16:21:25Z
dc.date.available2022-08-02T16:21:25Z
dc.date.issued2020-04-21
dc.description.abstractWe report the use of pulsed interleaved excitation (PIE)-fluorescence lifetime imaging microscopy (FLIM) to measure the activities of two different biosensor probes simultaneously in single living cells. Many genetically encoded biosensors rely on the measurement of Förster resonance energy transfer (FRET) to detect changes in biosensor conformation that accompany the targeted cell signaling event. One of the most robust ways of quantifying FRET is to measure changes in the fluorescence lifetime of the donor fluorophore using FLIM. The study of complex signaling networks in living cells demands the ability to track more than one of these cellular events at the same time. Here, we demonstrate how PIE-FLIM can separate and quantify the signals from different FRET-based biosensors to simultaneously measure changes in the activity of two cell signaling pathways in the same living cells in tissues. The imaging system described here uses selectable laser wavelengths and synchronized detection gating that can be tailored and optimized for each FRET pair. Proof-of-principle studies showing simultaneous measurement of cytosolic calcium and protein kinase A activity are shown, but the PIE-FLIM approach is broadly applicable to other signaling pathways.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationReissaus CA, Day KH, Mirmira RG, Dunn KW, Pavalko FM, Day RN. PIE-FLIM Measurements of Two Different FRET-Based Biosensor Activities in the Same Living Cells. Biophys J. 2020;118(8):1820-1829. doi:10.1016/j.bpj.2020.03.003en_US
dc.identifier.urihttps://hdl.handle.net/1805/29702
dc.language.isoen_USen_US
dc.publisherCell Pressen_US
dc.relation.isversionof10.1016/j.bpj.2020.03.003en_US
dc.relation.journalBiophysical Journalen_US
dc.rightsPublisher Policyen_US
dc.sourcePMCen_US
dc.subjectBiosensing techniquesen_US
dc.subjectFluorescence resonance energy transferen_US
dc.subjectFluorescent dyesen_US
dc.subjectFluorescence microscopyen_US
dc.titlePIE-FLIM Measurements of Two Different FRETBased Biosensor Activities in the Same Living Cellsen_US
dc.typeArticleen_US
ul.alternative.fulltexthttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7175463/en_US
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
main.pdf
Size:
2.13 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: