Faster colonoscope withdrawal time without impaired detection using EndoRings
dc.contributor.author | Thygesen, John C. | |
dc.contributor.author | Ponugoti, Prasanna | |
dc.contributor.author | Tippins, William W. | |
dc.contributor.author | Garcia, Jonathan R. | |
dc.contributor.author | Sullivan, Andrew W. | |
dc.contributor.author | Broadley, Heather M. | |
dc.contributor.author | Rex, Douglas K. | |
dc.contributor.department | Medicine, School of Medicine | en_US |
dc.date.accessioned | 2019-05-08T18:08:56Z | |
dc.date.available | 2019-05-08T18:08:56Z | |
dc.date.issued | 2018-08 | |
dc.description.abstract | Background and study aims: Mucosal exposure devices on the colonoscope tip have improved detection. We evaluated detection and procedure times in colonoscopies performed with EndoRings. Patients and methods: We had 14 endoscopists in a university practice trial EndoRings. We compared detection and procedure times to age- and indication-matched procedures by the same endoscopists. Results: There were 137 procedures with EndoRings. The adenoma detection rate was 44 % with EndoRings vs. 39 % without ( P = 0.39). Mean adenomas per colonoscopy (standard deviation) was 1.2 (2.3) with EndoRings vs. 0.9 (1.6) without ( P = 0.055). Mean insertion time with EndoRings was 6.2 (3.2) minutes vs. 6.6 (6.7) minutes without ( P = 0.81). Mean withdrawal time with EndoRings in all patients with or without polypectomy was 12.2 (5.3) minutes and 16.1 (10.3) minutes without ( P = 0.0005). Conclusion: EndoRings may allow faster withdrawal during colonoscopy without any reduction in detection. Prospective trials with mucosal exposure devices targeting procedure times as primary endpoints are warranted. | en_US |
dc.identifier.citation | Thygesen, J. C., Ponugoti, P., Tippins, W. W., Garcia, J. R., Sullivan, A. W., Broadley, H. M., & Rex, D. K. (2018). Faster colonoscope withdrawal time without impaired detection using EndoRings. Endoscopy international open, 6(8), E957–E960. doi:10.1055/a-0614-2052 | en_US |
dc.identifier.uri | https://hdl.handle.net/1805/19182 | |
dc.language.iso | en_US | en_US |
dc.publisher | Thieme | en_US |
dc.relation.isversionof | 10.1055/a-0614-2052 | en_US |
dc.relation.journal | Endoscopy International Open | en_US |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | PMC | en_US |
dc.subject | Mucosal exposure devices | en_US |
dc.subject | Colonoscopies | en_US |
dc.subject | EndoRings | en_US |
dc.title | Faster colonoscope withdrawal time without impaired detection using EndoRings | en_US |
dc.type | Article | en_US |