Clinical performance of intentionally tilted implants versus axially positioned implants: A systematic review

dc.contributor.authorLin, Wei-Shao
dc.contributor.authorEckert, Steven E.
dc.contributor.departmentProsthodontics, School of Dentistryen_US
dc.date.accessioned2019-06-13T18:28:16Z
dc.date.available2019-06-13T18:28:16Z
dc.date.issued2018-10
dc.description.abstractObjectives The aim of this review was to determine the clinical performance of dental implants that are intentionally tilted when compared with implants that are placed following the long axis of the residual alveolar ridge. Materials and methods A systematic review of the scientific literature using a predefined research question (PICO) and search strategy was undertaken. This search included five electronic databases. Two independent reviewers examined electronic databases and performed a manual review following search strategy to accomplish the item generation and reduction. Included articles were evaluated to determine the level of evidence. Data were extracted only from level I and level II studies, based on the Oxford Centre for Evidence‐based Medicine—Levels of Evidence (March 2009). If included studies were homogeneous in nature, data were to be accumulated. However, if included studies were heterogeneous in nature, only descriptive data would be reviewed and analyzed. Results A total of 811 articles were identified through the PICO question and search strategy. Detailed review of the abstracts and articles resulted in further item reduction, and 46 articles were included for full‐text review. A total of 42 articles were then selected for inclusion in the systematic review. The identified articles included two level I and 20 level II studies. In addition, 15 level IV, one gray literature, and four previous systematic reviews with meta‐analyses were also used in the study. The extracted data from the included studies demonstrated heterogeneity that prevented quantitative assessment, and only one level II study directly compared tilted and axially placed implants. Assessment of the descriptive data demonstrated no differences in implant survival, marginal bone loss, prosthesis survival, or patient‐reported outcome measures (PROMs) whether implants are placed axially or with intentional inclination of the coronal aspect of the implant toward the distal aspect of edentulous jaws. Conclusions Based upon the systematic review of the literature, an analysis of the descriptive data suggested no differences in clinical performance between implants that are placed in an axial position relative to the residual alveolar ridge when compared with implants that are intentionally tilted toward the distal aspect of edentulous jaws.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationLin, W.-S., & Eckert, S. E. (2018). Clinical performance of intentionally tilted implants versus axially positioned implants: A systematic review. Clinical Oral Implants Research, 29(S16), 78–105. https://doi.org/10.1111/clr.13294en_US
dc.identifier.urihttps://hdl.handle.net/1805/19603
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.isversionof10.1111/clr.13294en_US
dc.relation.journalClinical Oral Implants Researchen_US
dc.rightsAttribution-NonCommercial 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/3.0/us/*
dc.sourcePublisheren_US
dc.subjectclinical assessmenten_US
dc.subjectclinical researchen_US
dc.subjectclinical trialsen_US
dc.titleClinical performance of intentionally tilted implants versus axially positioned implants: A systematic reviewen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Lin_2018_clinical.pdf
Size:
1.49 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: