Automated Microaneurysms Detection in Retinal Images Using Radon Transform and Supervised Learning: Application to Mass Screening of Diabetic Retinopathy

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2021
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
IEEE
Abstract

Detection of red lesions in color retinal images is a critical step to prevent the development of vision loss and blindness associated with diabetic retinopathy (DR). Microaneurysms (MAs) are the most frequently observed and are usually the first lesions to appear as a consequence of DR. Therefore, their detection is necessary for mass screening of DR. However, detecting these lesions is a challenging task because of the low image contrast, and the wide variation of imaging conditions. Recently, the emergence of computer-aided diagnosis systems offers promising approaches to detect these lesions for diagnostic purposes. In this paper we focus on developing unsupervised and supervised techniques to cope intelligently with the MAs detection problem. In the first step, the retinal images are preprocessed to remove background variation in order to achieve a high level of accuracy in the detection. In the main processing step, important landmarks such as the optic nerve head and retinal vessels are detected and masked using the Radon transform (RT) and multi-overlapping windows. Finally, the MAs are detected and numbered by using a combination of RT and a supervised support vector machine classifier. The method was tested on three publicly available datasets and a local database comprising a total of 749 images. Detection performance was evaluated using sensitivity, specificity, and FROC analysis. From the image analysis viewpoint, DR was detected with a sensitivity of 100% and a specificity of 93% on average across all of these databases. Moreover, from lesion-based analysis the proposed approach detected the MAs with sensitivity of 95.7% with an average of 7 false positives per image. These results compare favourably with the best of the published results to date.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Tavakoli M, Mehdizadeh A, Aghayan A, Shahri RP, Ellis T, Dehmeshki J. Automated Microaneurysms Detection in Retinal Images Using Radon Transform and Supervised Learning: Application to Mass Screening of Diabetic Retinopathy. IEEE Access. 2021;9:67302-67314. doi:10.1109/ACCESS.2021.3074458
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
IEEE Access
Source
Publisher
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}