Development and validation of an objective scoring tool to evaluate surgical dissection: Dissection Assessment for Robotic Technique (DART)

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2021
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
American Urological Association Education and Research, Inc.
Abstract

Purpose: Evaluation of surgical competency has important implications for training new surgeons, accreditation, and improving patient outcomes. A method to specifically evaluate dissection performance does not yet exist. This project aimed to design a tool to assess surgical dissection quality.

Methods: Delphi method was used to validate structure and content of the dissection evaluation. A multi-institutional and multi-disciplinary panel of 14 expert surgeons systematically evaluated each element of the dissection tool. Ten blinded reviewers evaluated 46 de-identified videos of pelvic lymph node and seminal vesicle dissections during the robot-assisted radical prostatectomy. Inter-rater variability was calculated using prevalence-adjusted and bias-adjusted kappa. The area under the curve from receiver operating characteristic curve was used to assess discrimination power for overall DART scores as well as domains in discriminating trainees (≤100 robotic cases) from experts (>100).

Results: Four rounds of Delphi method achieved language and content validity in 27/28 elements. Use of 3- or 5-point scale remained contested; thus, both scales were evaluated during validation. The 3-point scale showed improved kappa for each domain. Experts demonstrated significantly greater total scores on both scales (3-point, p< 0.001; 5-point, p< 0.001). The ability to distinguish experience was equivalent for total score on both scales (3-point AUC= 0.92, CI 0.82-1.00, 5-point AUC= 0.92, CI 0.83-1.00).

Conclusions: We present the development and validation of Dissection Assessment for Robotic Technique (DART), an objective and reproducible 3-point surgical assessment to evaluate tissue dissection. DART can effectively differentiate levels of surgeon experience and can be used in multiple surgical steps.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Vanstrum EB, Ma R, Maya-Silva J, et al. Development and validation of an objective scoring tool to evaluate surgical dissection: Dissection Assessment for Robotic Technique (DART). Urol Pract. 2021;8(5):596-604. doi:10.1097/upj.0000000000000246
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Urology Practice
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}