Performance of a 62Zn/62Cu microgenerator in kit-based synthesis and delivery of [62Cu]Cu–ETS for PET perfusion imaging
dc.contributor.author | Ng, Yen | |
dc.contributor.author | Lacy, Jeffrey L. | |
dc.contributor.author | Fletcher, James W. | |
dc.contributor.author | Green, Mark A. | |
dc.contributor.department | Department of Radiology and Imaging Sciences, IU School of Medicine | en_US |
dc.date.accessioned | 2016-02-29T22:19:11Z | |
dc.date.available | 2016-02-29T22:19:11Z | |
dc.date.issued | 2014-09 | |
dc.description.abstract | The performance of a commercially produced 62Zn/62Cu microgenerator system, and an associated kit-based radiopharmaceutical synthesis method, was evaluated for clinical site production of [62Cu]Cu-ETS (ethylglyoxal bis(thiosemicarbazonato)copper(II)), an investigational agent for PET perfusion imaging. Using 37 generators, containing 1.84 ± 0.23 GBq 62Zn at 9:00 AM on the day of clinical use, a total of 45 patient doses of [62Cu]Cu-ETS (672 ± 172 MBq) were delivered without difficulty. 62Cu elution yields were high (approximately 90%), accompanied by extremely low 62Zn breakthrough (<0.001%). Radiopharmaceutical preparation, from the start-of-elution to time-of-injection, consumed less than five minutes. The 62Zn/62Cu microgenerator was a dependable source of short-lived positron-emitting 62Cu, and the kit-based synthesis proved to be rapid, robust, and highly reliable for “on-demand” delivery of [62Cu]Cu-ETS for PET perfusion imaging. | en_US |
dc.eprint.version | Author's manuscript | en_US |
dc.identifier.citation | Ng, Y., Lacy, J. L., Fletcher, J. W., & Green, M. A. (2014). Performance of a 62Zn/62Cu Microgenerator in Kit-Based Synthesis and Delivery of [62Cu]Cu-ETS for PET Perfusion Imaging. Applied Radiation and Isotopes : Including Data, Instrumentation and Methods for Use in Agriculture, Industry and Medicine, 91, 38–43. http://doi.org/10.1016/j.apradiso.2014.05.006 | en_US |
dc.identifier.uri | https://hdl.handle.net/1805/8594 | |
dc.language.iso | en_US | en_US |
dc.publisher | Elsevier B.V. | en_US |
dc.relation.isversionof | 10.1016/j.apradiso.2014.05.006 | en_US |
dc.relation.journal | Applied Radiation and Isotopes | en_US |
dc.rights | Publisher Policy | en_US |
dc.source | PMC | en_US |
dc.subject | 62Zn/62Cu generator | en_US |
dc.subject | PET radiopharmaceuticals | en_US |
dc.subject | [62Cu]Cu-ETS (copper(II) ethylglyoxal bis(thiosemicarbazone)) | en_US |
dc.subject | tumor perfusion | en_US |
dc.title | Performance of a 62Zn/62Cu microgenerator in kit-based synthesis and delivery of [62Cu]Cu–ETS for PET perfusion imaging | en_US |