Comparison of Artificial Intelligence and Eyeball Method in the Detection of Fatty Liver Disease
dc.contributor.author | Catron, Evan J. | |
dc.contributor.author | Passarelli, Robert P. | |
dc.contributor.author | Danielle, Wilmes | |
dc.contributor.author | Wei, Barry | |
dc.contributor.author | Le, Thi M.U. | |
dc.contributor.author | Li, Ping | |
dc.contributor.author | Zhang, Wenjun | |
dc.contributor.author | Lin, Jingmei | |
dc.contributor.author | Melcher, Mark L. | |
dc.contributor.author | Mihaylov, Plamen V. | |
dc.contributor.author | Kubal, Chandrashekhar A. | |
dc.contributor.author | Mangus, Robert S. | |
dc.contributor.author | Ekser, Burcin | |
dc.date.accessioned | 2023-09-18T14:13:25Z | |
dc.date.available | 2023-09-18T14:13:25Z | |
dc.date.issued | 2023-07-26 | |
dc.description.abstract | Background: Quantification of liver fat content relies on visual microscopic inspection of liver biopsies by pathologists. Their percent macrosteatosis (%MaS) estimation is vital in determining donor liver transplantability; however, the eyeball method may vary between observers. Overestimations of %MaS can potentially lead to the discard of viable donor livers. We hypothesize that artificial intelligence (AI) could be helpful in providing a more objective and accurate measurement of %MaS. Methods: Literature review identified HALO (image analysis) and U-Net (deep-learning) as high-accuracy AI programs capable of calculating %MaS in liver biopsies. We compared (i) an experienced pathologist’s and (ii) a transplant surgeon’s eyeball %MaS estimations from de-novo liver transplant (LT) biopsy samples taken 2h post-reperfusion to (iii) the HALO-calculated %MaS (Fig.1). 250 patients had undergone LT at Indiana University between 2020-2021, and 211 had sufficient data for inclusion. Each biopsy was digitized into 5 random non-overlapping tiles at 20x magnification (a total of 1,055 images). We used HALO software for analysis and set the minimum vacuole area to 10μm² to avoid the inclusion of microsteatosis. Microsteatosis was excluded by the pathologist and the surgeon by the eyeball method using the same 1,055 images. Each %MaS estimation was compared with early allograft dysfunction (EAD). EAD is defined by the presence of at least one of the following: INR >1.6 on postoperative day (POD) 7, total bilirubin >10mg/dL on POD7, or AST/ALT >2000IU/L within the first 7 days following LT. Results: Of 211 LTs, 42 (19.9%) had EAD. The mean %MaS estimation of pathologist and transplant surgeon were 6.3% (SD: 11.9%) and 3.2% (SD: 6.4%), respectively. HALO yielded a significantly lower mean %MaS of 2.6% (SD: 2.6%) than the pathologist’s eyeball method (p<0.001). The mean %MaS calculated by HALO was higher in EAD patients than in non-EAD (p=0.032), but this difference did not reach statistical significance in the pathologist’s estimation (p=0.069). Conclusions: Although mean %MaS measurements from all parties were mild (<10%), human eyeball estimations of %MaS were significantly higher than HALO’s %MaS. The HALO-calculated %MaS differed significantly between the EAD and non-EAD LTs which might suggest a possible correlation between the AI’s steatosis analysis and EAD outcomes. However, pathologic variables other than %MaS (necrosis or cholestasis) should be included in future analyses to determine whether %MaS is the dominant parameter predicting EAD. AI is a promising tool to quantify liver steatosis and will help pathologists and transplant surgeons predict liver transplant viability. | |
dc.description.sponsorship | NIH T35 Physician Scientist Training Program | |
dc.identifier.uri | https://hdl.handle.net/1805/35592 | |
dc.language.iso | en | |
dc.subject | transplant | |
dc.subject | surgery | |
dc.subject | allograft | |
dc.subject | biopsy | |
dc.subject | pathology | |
dc.subject | artificial intelligence | |
dc.subject | AI | |
dc.subject | hepatosteatosis | |
dc.title | Comparison of Artificial Intelligence and Eyeball Method in the Detection of Fatty Liver Disease |
Files
Original bundle
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.99 KB
- Format:
- Item-specific license agreed upon to submission
- Description: