Utilization of direct smears of thyroid fine‐needle aspirates for ancillary molecular testing: A comparison of two proprietary testing platforms

Date
2018-04
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Wiley
Abstract

Background Ancillary molecular testing has been recommended for thyroid fine‐needle aspirates (FNA) with indeterminate cytologic diagnoses. Rosetta Genomics and Interpace Diagnostics have developed assays that can utilize direct smears as the testing substrate.

Methods A retrospective study of indeterminate thyroid FNAs with known histologic follow‐up was performed. One Diff‐Quik‐stained smear and one Papanicolaou‐stained smear with similar cellularity (at least 60‐100 lesional cells) from each case were sent to Rosetta and Interpace, respectively, for analysis. The results were directly compared and correlated with the final histopathology. Neither company was aware of the follow‐up histologic findings in these cases.

Results A total of 10 thyroid FNAs were identified from our 2015 files. The cytologic diagnoses included follicular lesion of undetermined significance (FLUS, n = 5), follicular neoplasm/suspicious for follicular neoplasm (FN/SFN, n = 4), and suspicious for malignancy (SM, n = 1). Of the seven cases with benign histology, six smears were classified as benign by the RosettaGX microRNA classifier, and one case was designated as suspicious. Five cases were negative by both ThyGenX oncogene panel and ThyraMIR microRNA classifier. One case was negative by ThyGenX and positive on follow‐up ThyraMIR, and one case was positive for KRAS mutation and positive on ThyraMIR. Both the RosettaGX and ThyGenX/ThyraMIR tests demonstrated positive results for the three histologically malignant cases.

Conclusion This study demonstrates that two molecular testing platforms performed equally well using our stained direct smears. Both molecular tests revealed a 100% negative predictive rate. RosettaGX showed a 75% positive predictive value in comparison to 60% for ThyGenX/ThyraMIR.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Partyka, K. L., Randolph, M. L., Lawrence, K. A., Cramer, H., & Wu, H. H. (2018). Utilization of direct smears of thyroid fine-needle aspirates for ancillary molecular testing: A comparison of two proprietary testing platforms. Diagnostic Cytopathology, 46(4), 320–325. https://doi.org/10.1002/dc.23902
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Diagnostic Cytopathology
Rights
IUPUI Open Access Policy
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}