Method for Detection and Quantification of Non-Invasive Skin Sympathetic Nerve Activity

dc.contributor.authorLiu, Chun
dc.contributor.authorWong, Johnson
dc.contributor.authorDoytchinova, Anisiia
dc.contributor.authorChen, Peng-Sheng
dc.contributor.authorLin, Shien-Fong
dc.contributor.departmentMedicine, School of Medicineen_US
dc.date.accessioned2019-08-27T15:37:26Z
dc.date.available2019-08-27T15:37:26Z
dc.date.issued2018
dc.description.abstractSympathetic nerve activity is an important trigger of cardiac arrhythmia. Our laboratory recently developed a new method for non-invasive recording of the skin sympathetic nerve activity (SKNA) using conventional electrocardiography (ECG) patch electrodes. Recent studies showed that SKNA can adequately estimate sympathetic tone in humans. In order to improve the analysis of SKNA, we developed automatic standard assessment system based on the concept of microneurography and applied to non-invasive SKNA recording via 4 steps of signal processing. Every parameters in procedures can be manually selected by users in order to meet requirements. After using these signal processing, the results obtained by this system show improved nerve burst morphology and trend. Intuitive nerve discharge pattern and occurrence frequency can be automatically generated. Verification of the method with the cold water pressor test data further established the reliability and usefulness of the system. This new method offered a convenient tool to evaluate SKNA for comprehensive and detailed application in neurocardiology. The analysis system may facilitate the study between SKNA and cardiac arrhythmia, thus advance the field of neurocardiology research.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationLiu, C., Wong, J., Doytchinova, A., Chen, P., & Lin, S. (2018). Method for Detection and Quantification of Non-Invasive Skin Sympathetic Nerve Activity. 2018 International Conference on System Science and Engineering (ICSSE), 1–4. https://doi.org/10.1109/ICSSE.2018.8520024en_US
dc.identifier.urihttps://hdl.handle.net/1805/20605
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.isversionof10.1109/ICSSE.2018.8520024en_US
dc.relation.journal2018 International Conference on System Science and Engineeringen_US
dc.rightsPublisher Policyen_US
dc.sourceAuthoren_US
dc.subjectmicroneurographyen_US
dc.subjectskin sympathetic nerve activityen_US
dc.subjectnerve assessment systemen_US
dc.titleMethod for Detection and Quantification of Non-Invasive Skin Sympathetic Nerve Activityen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Liu_2019_method.pdf
Size:
579.68 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: