Dual-Energy CT for Quantification of Urinary Stone Composition in Mixed Stones: A Phantom Study

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2016-08
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
American Roentgen Ray Society
Abstract

Purpose

To demonstrate the feasibility of using dual-energy computed tomography to accurately quantify uric acid and non-uric-acid components in urinary stones having mixed composition. Materials and Methods

A total of 24 urinary stones were analyzed with microCT to serve as the reference standard for uric acid and non-uric-acid composition. These stones were placed in water phantoms to simulate body attenuation of slim to obese adults and scanned on a third-generation dual-source scanner using dual-energy modes adaptively selected based on phantom size. CT number ratio, which is distinct for different materials, was calculated for each pixel of the stones. Each pixel was then classified as uric acid and non-uric-acid by comparing the CT number ratio with preset thresholds ranging from 1.1 to 1.7. Minimal, maximal and root-mean-square errors were calculated by comparing composition to the reference standard and the threshold with the minimal root-mean-square-error was determined. A paired t-test was performed to compare the stone composition determined with dual-energy CT with the reference standard obtained with microCT. Results

The optimal CT number ratio threshold ranged from 1.27 to 1.55, dependent on phantom size. The root-mean-square error ranged from 9.60% to 12.87% across all phantom sizes. Minimal and maximal absolute error ranged from 0.04% to 1.24% and from 22.05% to 35.46%, respectively. Dual-energy CT and the reference microCT did not differ significantly on uric acid and non-uric-acid composition (P from 0.20 to 0.96, paired t-test). Conclusion

Accurate quantification of uric acid and non-uric-acid composition in mixed stones is possible using dual-energy CT.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Leng, S., Huang, A., Montoya, J., Duan, X., Williams, J. C., & McCollough, C. H. (2016). Quantification of Urinary Stone Composition in Mixed Stones Using Dual-Energy CT: A Phantom Study. AJR. American Journal of Roentgenology, 207(2), 321–329. http://doi.org/10.2214/AJR.15.15692
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
AJR American Journal of Roentgenology
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}