Challenges of Creating a Verifiable Building Energy Model

dc.contributor.authorLigade, J.
dc.contributor.authorSebastian, D.
dc.contributor.authorRazban, A.
dc.contributor.departmentMechanical and Energy Engineering, School of Engineering and Technologyen_US
dc.date.accessioned2020-09-17T19:54:47Z
dc.date.available2020-09-17T19:54:47Z
dc.date.issued2019
dc.description.abstractConducting an energy model simulation for building systems design is indispensable when designing for optimal energy efficiency. Without a critical understanding of the potential energy limitations and waste that a building might exhibit, the substantial financial increase of a project might inhibit the growth of environmental conservancy and progress in business. Computational software operated by professionals helps to sustain that growth. The Science Engineering & Technology (ET) building on the Indiana University - Purdue University Indianapolis campus provided the model for this study and allowed observation of the usability of three distinct software packages - eQUEST v3.65, Trace 700 v6.3.2, and EnergyPlus paired with OpenStudio V8.7.0 - and a comparison of the end results with actual utility data provided by Campus Facility Services. This was an attempt to identify the main challenges that building energy modeling software has yet to overcome and to evaluate the merits of the software packages regarding ease-of-use, detail, accuracy, and modeling options. It is shown that the two biggest challenges are 1) creating a model that accurately represents the physical building and its internal systems, and 2) accurate representation of usage and conditions to which the building will be subjected. The former can be mitigated by creating more user-friendly programs with a better system of checks and balances to identify errors in the physical model. The latter is highly complex, often due to the lack of data acquisition to represent the past and the absence of exacting foresight into the uses and conditions of the building. The results show that energy consumption can be calculated with error ranging of 11%-21% with eQUEST, between 18%-90% with Trane Trace 700 and between 5%-20% with EnergyPlus.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationLigade, J., Sebastian, D., & Razban, A. (2019). Challenges of Creating a Verifiable Building Energy Model. ASHRAE Transactions, 125(1), 20–29.en_US
dc.identifier.urihttps://hdl.handle.net/1805/23865
dc.language.isoenen_US
dc.publisherASHRAEen_US
dc.relation.journalASHRAE Transactionsen_US
dc.rightsPublisher Policyen_US
dc.sourceAuthoren_US
dc.subjectenergy model simulationen_US
dc.subjectbuilding systems designen_US
dc.subjectenergy efficiencyen_US
dc.titleChallenges of Creating a Verifiable Building Energy Modelen_US
dc.typeConference proceedingsen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ligade2019Challenges.pdf
Size:
556.91 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: