Feasibility of Using Inertial Measurement Units (IMUs) to Augment Cadaveric Temporal Training

Date
2025
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Wiley
Can't use the file because of accessibility barriers? Contact us with the title of the item, permanent link, and specifics of your accommodation need.
Abstract

Objective: Insertional speed of cochlear implant electrode arrays (EA) during surgery is correlated with force. Low insertional speed, and therefore force, may allow for preservation of intracochlear structures leading to improved outcomes. Given the importance of low insertional speeds, we investigate the feasibility of using inertial sensors for kinematic analysis during EA insertion to augment otolaryngology-head and neck surgery training.

Methods: Practicing otolaryngology surgeons were recruited and inertial measurement units (IMU; Metamotions+, MBIENTLAB Inc, San Jose, CA) consisting of accelerometers were used to measure hand speed during EA (Cochlear™Nucleus®CI522 cochlear implant with Slim Straight electrode, Cochlear Limited, Sydney, Australia) insertion into a cadaveric cochlea. A mixed regression model was utilized to determine differences in speed across trials within a surgeon.

Results: A total of nine trials were performed by three surgeons. The highest mean ± SD speed obtained was 8.4 ± 1.7 mm/s, and the highest speed was 22.5 mm/s. Mean speed was not significantly different across trials within surgeons (p > 0.05).

Discussion: IMUs are relatively inexpensive and relatively easy to use sensors that provide information on variables that may be of interest for otolaryngology resident training. The use of IMUs as part of advanced temporal training for cochlear electrode insertion can provide insight into hand speed, thereby allowing residents to train with specific regard to this variable. Future randomized-controlled trials can be carried out to determine whether IMUs are conducive to lower insertional speeds.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Wesson T, Ambike S, Patel R, et al. Feasibility of Using Inertial Measurement Units (IMUs) to Augment Cadaveric Temporal Training. Laryngoscope. 2025;135(4):1465-1471. doi:10.1002/lary.31878
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Laryngoscope
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}