Intrarater and Interrater Reliability of the Soong Classification for Distal Radius Volar Locking Plate Placement

dc.contributor.authorCreighton, James J., III
dc.contributor.authorJensen, Courtney D.
dc.contributor.authorKaplan, F. Thomas D.
dc.contributor.departmentOrthopaedic Surgery, School of Medicineen_US
dc.date.accessioned2019-02-07T19:52:28Z
dc.date.available2019-02-07T19:52:28Z
dc.date.issued2019
dc.description.abstractBackground: The purpose of this study was to analyze the intrarater and interrater reliability of the Soong classification for volar locking plate placement on a randomly selected, consecutive series of radiographs. Our hypothesis was that the classification would be reliable. Methods: Six physicians of differing levels of training (orthopedic surgery intern to fellowship-trained upper extremity staff) were asked to review 40 radiographs in a random order on 2 separate occasions, 4 weeks apart. All observers graded each image (0, 1, or 2) based on the corresponding Soong grade. A weighted κ was used to determine the intrarater agreement. The interrater agreement was determined using an intraclass coefficient: Results: The intrarater reliability using a weighted κ ranged from 0.229 (95% confidence interval [CI]: 0.048-0.411) to 0.946 (95% CI: 0.840-1.051). The interrater intraclass coefficient for Randomization 1 was 0.944 (95% 0.912-0.967) and Randomization 2 was 0.877 (95% CI: 0.797-0.930). Conclusion: The Soong classification is a reliable tool, both interrater and intrarater, for assessing distal radius volar locking plate placement. The classification system remained reliable despite a randomly selected, consecutive series of images and physician observers of varying levels of training.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationCreighton, J. J., Jensen, C. D., & Kaplan, F. T. D. (2018). Intrarater and Interrater Reliability of the Soong Classification for Distal Radius Volar Locking Plate Placement. HAND, 1558944718797347. https://doi.org/10.1177/1558944718797347en_US
dc.identifier.urihttps://hdl.handle.net/1805/18336
dc.language.isoenen_US
dc.publisherSageen_US
dc.relation.isversionof10.1177/1558944718797347en_US
dc.relation.journalHANDen_US
dc.rightsPublisher Policyen_US
dc.sourceAuthoren_US
dc.subjectvolar plate positionen_US
dc.subjectSoong classificationen_US
dc.subjectdistal radius fractureen_US
dc.titleIntrarater and Interrater Reliability of the Soong Classification for Distal Radius Volar Locking Plate Placementen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Creighton_2018_intrarater.pdf
Size:
186.29 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: