Diagnosis of Histoplasmosis Using the MVista Histoplasma Galactomannan Antigen Qualitative Lateral Flow–Based Immunoassay: A Multicenter Study

Date
2021-08-31
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Oxford University Press
Abstract

Background: Accurate and timely methods for the diagnosis of histoplasmosis in resource-limited countries are lacking. Histoplasma antigen detection by enzyme immunoassay (EIA) is widely used in the United States (US) but not in resource-limited countries, leading to missed or delayed diagnoses and poor outcomes. Lateral flow assays (LFAs) can be used in this setting.

Methods: Frozen urine specimens were submitted to MiraVista diagnostics for antigen testing from 3 medical centers in endemic areas of the US. They were blinded and tested for the MVista Histoplasma LFA. Patients were classified as controls or cases of histoplasmosis. Cases were divided into proven or probable; pulmonary or disseminated; immunocompetent or immunosuppressed; and mild, moderate, or severe.

Results: Three hundred fifty-two subjects were enrolled, including 66 cases (44 proven, 22 probable) and 286 controls. Most of the cases were immunocompromised (71%), and 46 had disseminated and 20 had pulmonary histoplasmosis. Four cases were mild, 42 moderate, and 20 severe. LFA and EIA were highly concordant (κ = 0.84). Sensitivity and specificity of the LFA were 78.8% and 99.3%, respectively. LFA sensitivity was higher in proven cases (93.2%), patients with disseminated (91.3%), moderate (78.6%), and severe disease (80%), and those with galactomannan levels >1.8 ng/mL (97.8%). Specificity was 99.3% in proven cases, 99.3% in patients with moderate or severe disease, and 96.8% in those with galactomannan levels >1.8 ng/mL. Cross-reactivity was noted with other endemic mycoses.

Conclusions: The MVista Histoplasma LFA meets the need for accurate rapid diagnosis of histoplasmosis in resource-limited countries, especially in patients with high disease burden, potentially reducing morbidity and mortality.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Abdallah W, Myint T, LaRue R, et al. Diagnosis of Histoplasmosis Using the MVista Histoplasma Galactomannan Antigen Qualitative Lateral Flow-Based Immunoassay: A Multicenter Study. Open Forum Infect Dis. 2021;8(9):ofab454. Published 2021 Aug 31. doi:10.1093/ofid/ofab454
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Open Forum Infectious Diseases
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Final published version
Full Text Available at
This item is under embargo {{howLong}}