On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of His-SYNC

dc.contributor.authorUpadhyay, Gaurav A.
dc.contributor.authorVijayaraman, Pugazhendi
dc.contributor.authorNayak, Hemal M.
dc.contributor.authorVerma, Nishant
dc.contributor.authorDandamudi, Gopi
dc.contributor.authorSharma, Parikshit S.
dc.contributor.authorSaleem, Moeen
dc.contributor.authorMandrola, John
dc.contributor.authorGenovese, Davide
dc.contributor.authorOren, Jess W.
dc.contributor.authorSubzposh, Faiz A.
dc.contributor.authorAziz, Zaid
dc.contributor.authorBeaser, Andrew
dc.contributor.authorShatz, Dalise
dc.contributor.authorBesser, Stephanie
dc.contributor.authorLang, Roberto M.
dc.contributor.authorTrohman, Richard G.
dc.contributor.authorKnight, Bradley P.
dc.contributor.authorTung, Roderick
dc.contributor.departmentMedicine, School of Medicineen_US
dc.date.accessioned2019-08-08T19:31:02Z
dc.date.available2019-08-08T19:31:02Z
dc.date.issued2019
dc.description.abstractBackground The His-SYNC pilot trial was the first randomized comparison between His bundle pacing in lieu of a left ventricular lead for cardiac resynchronization therapy (His-CRT) and biventricular pacing (BiV-CRT), but was limited by high rates of crossover. Objective To evaluate the results of the His-SYNC pilot trial utilizing treatment-received (TR) and per-protocol (PP) analyses. Methods The His-SYNC pilot was a multicenter, prospective, single-blinded, randomized, controlled trial comparing His-CRT vs BiV-CRT in patients meeting standard indications for CRT (eg, NYHA II–IV patients with QRS >120 ms). Crossovers were required based on prespecified criteria. The primary endpoints analyzed included improvement in QRS duration, left ventricular ejection fraction (LVEF), and freedom from cardiovascular (CV) hospitalization and mortality. Results Among 41 patients enrolled (aged 64 ± 13 years, 38% female, LVEF 28%, QRS 168 ± 18 ms), 21 were randomized to His-CRT and 20 to BiV-CRT. Crossover occurred in 48% of His-CRT and 26% of BiV-CRT. The most common reason for crossover from His-CRT was inability to correct QRS owing to nonspecific intraventricular conduction delay (n = 5). Patients treated with His-CRT demonstrated greater QRS narrowing compared to BiV (125 ± 22 ms vs 164 ± 25 ms [TR], P < .001;124 ± 19 ms vs 162 ± 24 ms [PP], P < .001). A trend toward higher echocardiographic response was also observed (80 vs 57% [TR], P = .14; 91% vs 54% [PP], P = .078). No significant differences in CV hospitalization or mortality were observed. Conclusions Patients receiving His-CRT on-treatment demonstrated superior electrical resynchronization and a trend toward higher echocardiographic response than BiV-CRT. Larger prospective studies may be justifiable with refinements in patient selection and implantation techniques to minimize crossovers.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationUpadhyay, G. A., Vijayaraman, P., Nayak, H. M., Verma, N., Dandamudi, G., Sharma, P. S., … Tung, R. (2019). On-treatment comparison between corrective his bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of his-sync. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2019.05.009en_US
dc.identifier.urihttps://hdl.handle.net/1805/20263
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.isversionof10.1016/j.hrthm.2019.05.009en_US
dc.relation.journalHeart Rhythmen_US
dc.rightsPublisher Policyen_US
dc.sourcePublisheren_US
dc.subjectbiventricular pacingen_US
dc.subjectcardiac resynchronization therapyen_US
dc.subjectheart failureen_US
dc.titleOn-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of His-SYNCen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Upadhyay_2019_on.pdf
Size:
10.13 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: