Validity of IPhone Apps to Measure Knee Range of Motion in Clinical Settings

dc.contributor.authorEvans, Eric
dc.contributor.authorStreepey, Jake
dc.contributor.authorBahamonde, Rafael
dc.date.accessioned2016-03-11T22:10:39Z
dc.date.available2016-03-11T22:10:39Z
dc.date.issued2015-04-17
dc.descriptionposter abstracten_US
dc.description.abstractRange of motion (ROM) of joints is a measure of musculoskeletal function in clinical and athletics settings. ROM in uniaxial joints is measured using a two-arm goniometer (GON). Although GON are inexpensive and can be used in different planes, there are limitation in accuracy and reproducibility. New IPhone apps have been developed to measure ROM using photography (PT tools, Dr.Goniometer and Photogoniometer), or the accelerometry and they also provide a permanent record of the measurement. The purpose of this study to compare the accuracy of the several IPhone apps against standard clinical [goniometer (GON)] and laboratory [electro-goniometer (EGON)] methods of measuring ROM. An EGON was attached the knee of 15 subjects knee while the performed five trials of knee extensionflexion). Three photography and one accelerometer based apps were compared against the EGON. The EGON data were compared against the GON used in clinical settings. Intraclass correlation (ICC) between methods and the Bland-Altman method (BAM) of assessing clinical agreement were used to determine validity. The ICC between the EGON and GON was r =.969 and with a BAM showing good clinical agreement between the two techniques. ICC of the photography based apps ranged from (.709-.721) and the accelerometer based goniometer was .671. The results of the BAM showed moderate to poor agreement between the methods, which indicate the some of the apps may not be suitable to use in clinical settings. The small screen size of the IPhone makes it difficult to accurately identify the joints centers. Small errors on placing the joint centers can lead to large errors of the knee joint angle. Accelerometer based apps are difficult to align and can be affected by muscle and adipose tissue of leg. It is possible that photography based apps when used on an IPad will provide better accuracy and be suitable to clinical settings.en_US
dc.identifier.citationEric Evans, Jake Streepey, and Rafael Bahamonde. (2015, April 17). Validity of IPhone Apps to Measure Knee Range of Motion in Clinical Settings. Poster session presented at IUPUI Research Day 2015, Indianapolis, Indiana.en_US
dc.identifier.urihttps://hdl.handle.net/1805/8820
dc.language.isoen_USen_US
dc.publisherOffice of the Vice Chancellor for Researchen_US
dc.subjectIPhone Appsen_US
dc.subjectRange of motion (ROM)en_US
dc.subjectjointsen_US
dc.subjectmusculoskeletal functionen_US
dc.subjectKneesen_US
dc.subjectClinical Settingsen_US
dc.titleValidity of IPhone Apps to Measure Knee Range of Motion in Clinical Settingsen_US
dc.typePosteren_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Evans-Validity.pdf
Size:
8.04 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: