Validity of IPhone Apps to Measure Knee Range of Motion in Clinical Settings

If you need an accessible version of this item, please submit a remediation request.
Date
2015-04-17
Language
American English
Embargo Lift Date
Department
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Office of the Vice Chancellor for Research
Abstract

Range of motion (ROM) of joints is a measure of musculoskeletal function in clinical and athletics settings. ROM in uniaxial joints is measured using a two-arm goniometer (GON). Although GON are inexpensive and can be used in different planes, there are limitation in accuracy and reproducibility. New IPhone apps have been developed to measure ROM using photography (PT tools, Dr.Goniometer and Photogoniometer), or the accelerometry and they also provide a permanent record of the measurement. The purpose of this study to compare the accuracy of the several IPhone apps against standard clinical [goniometer (GON)] and laboratory [electro-goniometer (EGON)] methods of measuring ROM. An EGON was attached the knee of 15 subjects knee while the performed five trials of knee extensionflexion). Three photography and one accelerometer based apps were compared against the EGON. The EGON data were compared against the GON used in clinical settings. Intraclass correlation (ICC) between methods and the Bland-Altman method (BAM) of assessing clinical agreement were used to determine validity. The ICC between the EGON and GON was r =.969 and with a BAM showing good clinical agreement between the two techniques. ICC of the photography based apps ranged from (.709-.721) and the accelerometer based goniometer was .671. The results of the BAM showed moderate to poor agreement between the methods, which indicate the some of the apps may not be suitable to use in clinical settings. The small screen size of the IPhone makes it difficult to accurately identify the joints centers. Small errors on placing the joint centers can lead to large errors of the knee joint angle. Accelerometer based apps are difficult to align and can be affected by muscle and adipose tissue of leg. It is possible that photography based apps when used on an IPad will provide better accuracy and be suitable to clinical settings.

Description
poster abstract
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Eric Evans, Jake Streepey, and Rafael Bahamonde. (2015, April 17). Validity of IPhone Apps to Measure Knee Range of Motion in Clinical Settings. Poster session presented at IUPUI Research Day 2015, Indianapolis, Indiana.
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Source
Alternative Title
Type
Poster
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Full Text Available at
This item is under embargo {{howLong}}