Twenty-Four-Hour Urine Phosphorus as a Biomarker of Dietary Phosphorus Intake and Absorption in CKD: A Secondary Analysis from a Controlled Diet Balance Study

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2018-07-06
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
American Society of Nephrology
Abstract

BACKGROUND AND OBJECTIVES:

Twenty-four-hour urine phosphorus is commonly used as a surrogate measure for phosphorus intake and absorption in research studies, but its reliability and accuracy are unproven in health or CKD. This secondary analysis sought to determine the reliability and accuracy of 24-hour urine phosphorus as a biomarker of phosphorus intake and absorption in moderate CKD. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS:

Eight patients with stage 3-4 CKD participated in 2-week balance studies with tightly controlled phosphorus and calcium intakes. Thirteen 24-hour urine collections per patient were analyzed for variability and reliability of 24-hour urine phosphorus and phosphorus-to-creatinine ratio. The accuracy of 24-hour urine phosphorus to predict phosphorus intake was determined using a published equation. The relationships of 24-hour urine phosphorus with phosphorus intake, net absorption, and retention were determined. RESULTS:

There was wide day-to-day variation in 24-hour urine phosphorus within and among subjects (coefficient of variation of 30% and 37%, respectively). Two 24-hour urine measures were needed to achieve ≥75% reliability. Estimating dietary phosphorus intake from a single 24-hour urine resulted in underestimation up to 98% in some patients and overestimation up to 79% in others. Twenty-four-hour urine phosphorus negatively correlated with whole-body retention but was not related to net absorption. CONCLUSIONS:

From a sample of eight patients with moderate CKD on a tightly controlled dietary intake, 24-hour urine phosphorus was highly variable and did not relate to dietary phosphorus intake or absorption, rather it inversely related to phosphorus retention.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Stremke, E. R., McCabe, L. D., McCabe, G. P., Martin, B. R., Moe, S. M., Weaver, C. M., … Hill Gallant, K. M. (2018). Twenty-Four-Hour Urine Phosphorus as a Biomarker of Dietary Phosphorus Intake and Absorption in CKD: A Secondary Analysis from a Controlled Diet Balance Study. Clinical journal of the American Society of Nephrology : CJASN, 13(7), 1002–1012. doi:10.2215/CJN.00390118
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Clinical journal of the American Society of Nephrology
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
This item is under embargo {{howLong}}