dc.descriptionposter abstracten_US
dc.description.abstractIntroduction Compared to babies born at full-term, premature and small babies are more susceptible to hypothermia (low body temperature), and more likely to perish, especially in countries with limited resources. One method for keeping babies warm in these settings is Kangaroo Mother Care (KMC), in which the mother and baby are in skin-to-skin contact. The NeoWarm project is focused on creating an affordable, effective, and feasible biomedical device that will allow caregivers in resource-limited areas to perform either KMC or use the device in a “stand-alone” mode to prevent hypothermia among vulnerable babies. Methods The NeoWarm project was composed of two teams of students from biomedical engineering (BME) and public health. The primary objective of the BME team was to perform engineering verification of an existing NeoWarm prototype. Methods included: (1) troubleshooting to determine existing functionality of the device; (2) reviewing the previous circuit design; (3) modifying the design to make it more efficient; (4) creating new circuit schematics utilizing revised instrumentation; (5) developing a LED light alarm system, to provide visual confirmation to caregivers of device functioning. The revised schematics were then (6) utilized to build a new circuit which was (7) integrated into the device. Results Successful engineering verification was conducted, and a revised prototype was created which performed crucial device tasks including: (1) continuous body temperature monitoring of the infant while in the device, in both KMC and stand-alone modes; (2) automatic triggering of the heating element when the infant’s body temperature drops; (3) consistent visual feedback as to device readings and functioning mode (e.g., “cold/heating” = blue; “temperature stable” = white; “too hot” = red). Conclusion The NeoWarm prototype is more efficient, effective, and robust. These strides should allow for future progression of the NeoWarm device towards becoming a viable solution to support the health of neonates around the world.en_US
dc.identifier.citationDustin Moore. 2016, April 8. NeoWarm: Engineering verification for a built-prototype of a biomedical device to prevent newborn hypothermia. Poster session presented at IUPUI Research Day 2016, Indianapolis, Indiana.en_US
dc.identifier.urihttps://hdl.handle.net/1805/10385
dc.language.isoen_USen_US
dc.publisherOffice of the Vice Chancellor for Researchen_US
dc.subjectnewborn hypothermiaen_US
dc.subjectNeoWarmen_US
dc.subjectKangaroo Mother Care (KMC)en_US
dc.subjectlow body temperatureen_US
dc.titleNeoWarm: Engineering verification for a built-prototype of a biomedical device to prevent newborn hypothermiaen_US
dc.typePosteren_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Moore.pdf
Size:
21.61 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.88 KB
Format:
Item-specific license agreed upon to submission
Description: