Retrospective Detection and Suppression of Dark-Rim Artifacts in First-Pass Perfusion Cardiac MRI Enabled by Deep Learning

dc.contributor.authorUnal, Hazar Benan
dc.contributor.authorBeaulieu, Taylor
dc.contributor.authorRivero, Luis Zamudio
dc.contributor.authorDharmakumar, Rohan
dc.contributor.authorSharif, Behzad
dc.contributor.departmentMedicine, School of Medicine
dc.date.accessioned2023-11-16T12:30:10Z
dc.date.available2023-11-16T12:30:10Z
dc.date.issued2021
dc.description.abstractThe dark-rim artifact (DRA) remains an important challenge in the routine clinical use of first-pass perfusion (FPP) cardiac magnetic resonance imaging (cMRI). The DRA mimics the appearance of perfusion defects in the subendocardial wall and reduces the accuracy of diagnosis in patients with suspected ischemic heart disease. The main causes for DRA are known to be Gibbs ringing and bulk motion of the heart. The goal of this work is to propose a deep-learning-enabled automatic approach for the detection of motion-induced DRAs in FPP cMRI datasets. To this end, we propose a new algorithm that can detect the DRA in individual time frames by analyzing multiple reconstructions of the same time frame (k-space data) with varying temporal windows. In addition to DRA detection, our approach is also capable of suppressing the extent and severity of DRAs as a byproduct of the same reconstruction-analysis process. In this proof-of-concept study, our proposed method showed a good performance for automatic detection of subendocardial DRAs in stress perfusion cMRI studies of patients with suspected ischemic heart disease. To the best of our knowledge, this is the first approach that performs deep-learning-enabled detection and suppression of DRAs in cMRI.
dc.eprint.versionAuthor's manuscript
dc.identifier.citationUnal HB, Beaulieu T, Rivero LZ, Dharmakumar R, Sharif B. Retrospective Detection and Suppression of Dark-Rim Artifacts in First-Pass Perfusion Cardiac MRI Enabled by Deep Learning. Annu Int Conf IEEE Eng Med Biol Soc. 2021;2021:4079-4085. doi:10.1109/EMBC46164.2021.9630270
dc.identifier.urihttps://hdl.handle.net/1805/37081
dc.language.isoen_US
dc.publisherIEEE
dc.relation.isversionof10.1109/EMBC46164.2021.9630270
dc.relation.journalAnnual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)
dc.rightsPublisher Policy
dc.sourcePMC
dc.subjectDeep learning
dc.subjectMagnetic resonance imaging
dc.subjectMyocardial perfusion imaging
dc.subjectPerfusion
dc.titleRetrospective Detection and Suppression of Dark-Rim Artifacts in First-Pass Perfusion Cardiac MRI Enabled by Deep Learning
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
nihms-1874482.pdf
Size:
1.61 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: