A Comparison of Simple Analytical Methods for Determination of Fluoride in Microlitre-Volume Plasma Samples

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2019-04
Language
English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Karger
Abstract

The aim was to compare potential methods for fluoride analysis in microlitre-volume plasma samples containing nano-gram amounts of fluoride. Methods: A group of 4 laboratories analysed a set of standardised biological samples as well as plasma to determine fluoride concentration using 3 methods. In Phase-1, fluoride analysis was carried out using the established hexamethyldisiloxane (HMDS)-diffusion method (1 mL-aliquot/analysis) to obtain preliminary measurement of agreement between the laboratories. In Phase-2, the laboratories analysed the same samples using a micro-diffusion method and known-addition technique with 200 µL-aliquot/analysis. Coefficients of Variation (CVs) and intra-class correlation coefficients (ICCs) were estimated using analysis of variance to evaluate the amount of variation within- and between-laboratories. Based on the results of the Phase-2 analysis, 20 human plasma samples were analysed and compared using the HMDS-diffusion method and known-addition technique in Phase-3. Results: Comparison of Phase-1 results showed no statistically significant difference among the laboratories for the overall data set. The mean between- and within-laboratory CVs and ICCs were < 0.13 and ≥0.99, respectively, indicating very low variability and excellent reliability. In Phase-2, the overall results for between-laboratory variability showed a poor CV (1.16) and ICC (0.44) for the micro-diffusion method, whereas with the known-addition technique the corresponding values were 0.49 and 0.83. Phase-3 results showed no statistically significant difference in fluoride concentrations of the plasma samples measured with HMDS-diffusion method and known- addition technique, with a mean (SE) difference of 0.002 (0.003) µg/mL. In conclusion, the known-addition technique could be a suitable alternative for the measurement of fluoride in plasma with microlitre-volume samples.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Zohoori, F. V., Maguire, A., Martinez-Mier, E. A., Buzalaf, M. A. R., Sanderson, R., & Eckert, G. J. (2019). A Comparison of Simple Analytical Methods for Determination of Fluoride in Microlitre-Volume Plasma Samples. Caries Research, 53(3), 275–283. https://doi.org/10.1159/000492339
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Caries Research
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}