Ad hoc Hybrid Synaptic Junctions to Detect Nerve Stimulation and its Application to Detect Onset of Diabetic Polyneuropathy

If you need an accessible version of this item, please email your request to digschol@iu.edu so that they may create one and provide it to you.
Date
2020-12
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

We report a minimally invasive, synaptic transistor-based construct to monitor in vivo neuronal activity via a longitudinal study in mice and use depolarization time from measured data to predict the onset of polyneuropathy. The synaptic transistor is a three-terminal device in which ionic coupling between pre- and post-synaptic electrodes provides a framework for sensing low-power (sub μW) and high-bandwidth (0.1–0.5kHz) ionic currents. A validated first principles-based approach is discussed to demonstrate the significance of this sensing framework and we introduce a metric, referred to as synaptic efficiency to quantify structural and functional properties of the electrodes in sensing. The application of this framework for in vivo neuronal sensing requires a post-synaptic electrode and its reference electrode and the tissue becomes the pre-synaptic signal. The ionic coupling resembles axo-axonic junction and hence we refer to this framework as an ad hoc synaptic junction. We demonstrate that this arrangement can be applied to measure excitability of sciatic nerves due to a stimulation of the footpad in cohorts of m+/db and db/db mice for detecting loss in sensitivity and onset of polyneuropathy. The signal attributes were subsequently integrated with machine learning-based framework to identify the probability of polyneuropathy and to detect the onset of diabetic polyneuropathy.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Gupta S, Ghatak S, Hery T, et al. Ad hoc hybrid synaptic junctions to detect nerve stimulation and its application to detect onset of diabetic polyneuropathy. Biosens Bioelectron. 2020;169:112618. doi:10.1016/j.bios.2020.112618
ISSN
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
Biosensors and Bioelectronics
Source
PMC
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}