Blood lead level in Chinese adults with and without coronary artery disease

dc.contributor.authorLi, Shi-Hong
dc.contributor.authorZhang, Hong-Ju
dc.contributor.authorLi, Xiao-Dong
dc.contributor.authorCui, Jian
dc.contributor.authorCheng, Yu-Tong
dc.contributor.authorWang, Qian
dc.contributor.authorWang, Su
dc.contributor.authorKrittanawong, Chayakrit
dc.contributor.authorEl-Am, Edward A.
dc.contributor.authorBou Chaaya, Rody G.
dc.contributor.authorWu, Xiang-Yu
dc.contributor.authorGu, Wei
dc.contributor.authorLiu, Hong-Hong
dc.contributor.authorYan, Xian-Liang
dc.contributor.authorLi, Zhi-Zhong
dc.contributor.authorYang, Shi-Wei
dc.contributor.authorSun, Tao
dc.contributor.departmentMedicine, School of Medicineen_US
dc.date.accessioned2023-04-14T15:06:25Z
dc.date.available2023-04-14T15:06:25Z
dc.date.issued2021
dc.description.abstractBackground: The Trial to Assess Chelation Therapy study found that edetate disodium (disodium ethylenediaminetetraacetic acid) chelation therapy significantly reduced the incidence of cardiac events in stable post-myocardial infarction patients, and a body of epidemiological data has shown that accumulation of biologically active metals, such as lead and cadmium, is an important risk factor for cardiovascular disease. However, limited studies have focused on the relationship between angiographically diagnosed coronary artery disease (CAD) and lead exposure. This study compared blood lead level (BLL) in Chinese patients with and without CAD. Methods: In this prospective, observational study, 450 consecutive patients admitted to Beijing Anzhen Hospital with suspected CAD from November 1, 2018, to January 30, 2019, were enrolled. All patients underwent coronary angiography, and an experienced heart team calculated the SYNTAX scores (SXscore) for all available coronary angiograms. BLLs were determined with atomic absorption spectrophotometry and compared between patients with angiographically diagnosed CAD and those without CAD. Results: In total, 343 (76%) patients had CAD, of whom 42% had low (0-22), 22% had intermediate (23-32), and 36% had high (≥ 33) SXscore. BLLs were 36.8 ± 16.95 μg/L in patients with CAD and 31.2 ± 15.75 μg/L in those without CAD (P = 0.003). When BLLs were categorized into three groups (low, middle, high), CAD prevalence increased with increasing BLLs (P < 0.05). In the multivariate regression model, BLLs were associated with CAD (odds ratio (OR): 1.023, 95% confidence interval (CI): 1.008-1.039; P = 0.0017). OR in the high versus low BLL group was 2.36 (95% CI: 1.29-4.42,P = 0.003). Furthermore, BLLs were independently associated with intermediate and high SXscore (adjusted OR: 1.050, 95% CI: 1.036-1.066; P < 0.0001). Conclusion: BLLs were significantly associated with angiographically diagnosed CAD. Furthermore, BLLs showed excellent predictive value for SXscore, especially for complex coronary artery lesions.en_US
dc.eprint.versionFinal published versionen_US
dc.identifier.citationLi SH, Zhang HJ, Li XD, et al. Blood lead level in Chinese adults with and without coronary artery disease. J Geriatr Cardiol. 2021;18(11):857-866. doi:10.11909/j.issn.1671-5411.2021.11.004en_US
dc.identifier.urihttps://hdl.handle.net/1805/32396
dc.language.isoen_USen_US
dc.publisherChina Scienceen_US
dc.relation.isversionof10.11909/j.issn.1671-5411.2021.11.004en_US
dc.relation.journalJournal of Geriatric Cardiologyen_US
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.sourcePMCen_US
dc.subjectCardiac eventen_US
dc.subjectCardiovascular diseaseen_US
dc.subjectCoronary angiographyen_US
dc.subjectCoronary artery diseaseen_US
dc.subjectBlood lead levelen_US
dc.titleBlood lead level in Chinese adults with and without coronary artery diseaseen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
jgc-18-11-857.pdf
Size:
3.39 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: