AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry-mass spectrometry

dc.contributor.authorLee, Joon-Yong
dc.contributor.authorBilbao, Aivett
dc.contributor.authorConant, Christopher R.
dc.contributor.authorBloodsworth, Kent J.
dc.contributor.authorOrton, Daniel J.
dc.contributor.authorZhou, Mowei
dc.contributor.authorWilson, Jesse W.
dc.contributor.authorZheng, Xueyun
dc.contributor.authorWebb, Ian K.
dc.contributor.authorLi, Ailin
dc.contributor.authorHixson, Kim K.
dc.contributor.authorFjeldsted, John C.
dc.contributor.authorIbrahim, Yehia M.
dc.contributor.authorPayne, Samuel H.
dc.contributor.authorJansson, Christer
dc.contributor.authorSmith, Richard D.
dc.contributor.authorMetz, Thomas O.
dc.contributor.departmentChemistry and Chemical Biology, School of Science
dc.date.accessioned2023-08-28T16:41:08Z
dc.date.available2023-08-28T16:41:08Z
dc.date.issued2021
dc.description.abstractMotivation: Ion mobility spectrometry (IMS) separations are increasingly used in conjunction with mass spectrometry (MS) for separation and characterization of ionized molecular species. Information obtained from IMS measurements includes the ion's collision cross section (CCS), which reflects its size and structure and constitutes a descriptor for distinguishing similar species in mixtures that cannot be separated using conventional approaches. Incorporating CCS into MS-based workflows can improve the specificity and confidence of molecular identification. At present, there is no automated, open-source pipeline for determining CCS of analyte ions in both targeted and untargeted fashion, and intensive user-assisted processing with vendor software and manual evaluation is often required. Results: We present AutoCCS, an open-source software to rapidly determine CCS values from IMS-MS measurements. We conducted various IMS experiments in different formats to demonstrate the flexibility of AutoCCS for automated CCS calculation: (i) stepped-field methods for drift tube-based IMS (DTIMS), (ii) single-field methods for DTIMS (supporting two calibration methods: a standard and a new enhanced method) and (iii) linear calibration for Bruker timsTOF and non-linear calibration methods for traveling wave based-IMS in Waters Synapt and Structures for Lossless Ion Manipulations. We demonstrated that AutoCCS offers an accurate and reproducible determination of CCS for both standard and unknown analyte ions in various IMS-MS platforms, IMS-field methods, ionization modes and collision gases, without requiring manual processing. Availability and implementation: https://github.com/PNNL-Comp-Mass-Spec/AutoCCS. Supplementary information: Supplementary data are available at Bioinformatics online. Demo datasets are publicly available at MassIVE (Dataset ID: MSV000085979).
dc.eprint.versionFinal published version
dc.identifier.citationLee JY, Bilbao A, Conant CR, et al. AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry-mass spectrometry. Bioinformatics. 2021;37(22):4193-4201. doi:10.1093/bioinformatics/btab429
dc.identifier.urihttps://hdl.handle.net/1805/35188
dc.language.isoen_US
dc.publisherOxford University Press
dc.relation.isversionof10.1093/bioinformatics/btab429
dc.relation.journalBioinformatics
dc.rightsAttribution 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourcePMC
dc.subjectIon mobility spectrometry
dc.subjectIons
dc.subjectMass spectrometry
dc.subjectSoftware
dc.titleAutoCCS: automated collision cross-section calculation software for ion mobility spectrometry-mass spectrometry
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
btab429.pdf
Size:
948.36 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: