Suturing of the Arachnoid Membrane for Reconstruction of the Cisterna Magna: Technical Considerations

Date
2021-10
Language
American English
Embargo Lift Date
Committee Members
Degree
Degree Year
Department
Grantor
Journal Title
Journal ISSN
Volume Title
Found At
Elsevier
Abstract

Background Postoperative cerebrospinal fluid (CSF) fistula following cranial or spinal surgery is associated with increased morbidity and mortality. To prevent CSF fistulas, various techniques have been described. Here, we describe the arachnoid membrane continuous-running suture technique in cisterna magna reconstruction for preventing postoperative CSF leakage.

Methods After craniotomy and dural opening, the incision of the arachnoid of the cisterna magna was performed using a diamond blade. To prevent the arachnoid from drying out and shrinking during surgery, it was periodically irrigated with warm saline solution. Posterior fossa surgery was performed. When closing the membranes, the arachnoid membrane was closed with the running-suture technique. After the first surgical knot was made in the cranial end of the arachnoid opening, continuous suturing with a 2-mm distance between the stitches was performed without stretching them. After every 3 stitches, the free end of the thread was pulled gently along the suturing axis, and the edges of the arachnoid were closed. After the arachnoid edges were approximated, the surgical knot was tied. Watertight closure was checked by performing the Valsalva maneuver at the end of the surgery.

Results No CSF leakages were observed after surgery.

Conclusions Arachnoid membrane suturing seems to be safe and effective in preventing postoperative CSF leakage and CSF-related complications. Using continuous running suturing alone, without any sealant, might be effective in cases with untraumatized arachnoid membrane.

Description
item.page.description.tableofcontents
item.page.relation.haspart
Cite As
Eroglu, U., Büyüktepe, M., Zaimoğlu, M., Kahilogullari, G., Ugur, H. C., Ünlü, M. A., & Cohen-Gadol, A. (2021). Suturing of the Arachnoid Membrane for Reconstruction of the Cisterna Magna: Technical Considerations. World Neurosurgery, 154, e724–e728. https://doi.org/10.1016/j.wneu.2021.07.129
ISSN
18788750
Publisher
Series/Report
Sponsorship
Major
Extent
Identifier
Relation
Journal
World Neurosurgery
Rights
IUPUI Open Access Policy
Source
Author
Alternative Title
Type
Article
Number
Volume
Conference Dates
Conference Host
Conference Location
Conference Name
Conference Panel
Conference Secretariat Location
Version
Author's manuscript
Full Text Available at
This item is under embargo {{howLong}}