A smartphone based method for mouse fundus imaging

dc.contributor.authorPeng, Michael
dc.contributor.authorPark, Bomina
dc.contributor.authorHarikrishnan, Hemavathy
dc.contributor.authorJahan, Sultana N.
dc.contributor.authorDai, Jiannong
dc.contributor.authorRayana, Naga Pradeep
dc.contributor.authorSugali, Chenna Kesavulu
dc.contributor.authorSharma, Tasneem P.
dc.contributor.authorImanishi, Sanae
dc.contributor.authorImanishi, Yoshikazu
dc.contributor.authorCorson, Timothy W.
dc.contributor.authorMao, Weiming
dc.contributor.departmentOphthalmology, School of Medicineen_US
dc.date.accessioned2023-06-16T10:01:17Z
dc.date.available2023-06-16T10:01:17Z
dc.date.issued2021
dc.description.abstractNoninvasive in vivo imaging of the mouse retina is essential for eye research. However, imaging the mouse fundus is challenging due to its small size and requires specialized equipment, maintenance, and training. These issues hinder the routine evaluation of the mouse retina. In this study, we developed a noncontact imaging system consisting of a smartphone, a 90D condensing lens, a homemade light diaphragm, a tripod, and a Bluetooth remote. With minimal training, examiners were able to capture fundus images from the mouse retina. We also found that fundus images captured using our system from wild type mice, mice with laser-induced retinal injury, and a mouse model of retinitis pigmentosa showed a quality similar to those captured using a commercial fundus camera. These images enabled us to identify normal structures and pathological changes in the mouse retina. Additionally, fluorescein angiography was possible with the smartphone system. We believe that the smartphone imaging system is low cost, simple, accessible, easy to operate, and suitable for the routine screening and examination of the mouse eye.en_US
dc.eprint.versionAuthor's manuscripten_US
dc.identifier.citationPeng M, Park B, Harikrishnan H, et al. A smartphone based method for mouse fundus imaging. Exp Eye Res. 2021;206:108530. doi:10.1016/j.exer.2021.108530en_US
dc.identifier.urihttps://hdl.handle.net/1805/33798
dc.language.isoen_USen_US
dc.publisherElsevieren_US
dc.relation.isversionof10.1016/j.exer.2021.108530en_US
dc.relation.journalExperimental Eye Researchen_US
dc.rightsPublisher Policyen_US
dc.sourcePMCen_US
dc.subjectFundus imagingen_US
dc.subjectFluorescein angiographyen_US
dc.subjectLaser-induced retinal injuryen_US
dc.subjectMouse retinaen_US
dc.subjectRetinitis pigmentosaen_US
dc.subjectSmartphoneen_US
dc.titleA smartphone based method for mouse fundus imagingen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
nihms-1681120.pdf
Size:
566.6 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: