dc.description.abstractRuptured vertebrobasilar dissecting aneurysms require urgent, often challenging treatment as they have with a high re-hemorrhage rate within the first 24 hours. The patient is a 57-year-old woman who presented with severe-sudden onset headache. Further work up showed a ruptured dissecting aneurysm of the caudal loop of the posterior inferior cerebellar artery (PICA) with associated narrowing distally, in the ascending limb. The aneurysm was immediately occluded with a Woven Endobridge (WEB) device (MicroVention, Tustin, CA, USA) while flow diversion treatment of the diseased ascending limb was postponed. Follow-up angiography three months later showed complete occlusion of the aneurysm, as well as healing of the diseased distal vessel, obviating the need for further intervention. WEB embolization of a ruptured dissecting posterior circulation aneurysm provided an excellent outcome for this patient.en_US
dc.identifier.citationKhattar NK, White AC, Cruz AS, et al. Woven Endobridge device for treatment of dissection-related PICA aneurysm. Interv Neuroradiol. 2021;27(3):388-390. doi:10.1177/1591019920968349en_US
dc.identifier.urihttps://hdl.handle.net/1805/34203
dc.language.isoen_USen_US
dc.publisherSageen_US
dc.relation.isversionof10.1177/1591019920968349en_US
dc.relation.journalInterventional Neuroradiologyen_US
dc.rightsPublisher Policyen_US
dc.sourcePMCen_US
dc.subjectPICA aneurysmen_US
dc.subjectPosterior inferior cerebellar arteryen_US
dc.subjectWoven Endobridgeen_US
dc.subjectWEB deviceen_US
dc.subjectAneurysmen_US
dc.subjectDissectionen_US
dc.titleWoven Endobridge device for treatment of dissection-related PICA aneurysmen_US
dc.typeArticleen_US
ul.alternative.fulltexthttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8190937/en_US
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Woven Endobridge device for treatment of dissection-related PICA aneurysm - PMC.pdf
Size:
537.68 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.99 KB
Format:
Item-specific license agreed upon to submission
Description: