Woven Endobridge device for treatment of dissection-related PICA aneurysm
dc.contributor.author | Khattar, Nicolas K. | |
dc.contributor.author | White, Andrew C. | |
dc.contributor.author | Cruz, Aurora S. | |
dc.contributor.author | Adams, Shawn W. | |
dc.contributor.author | Meyer, Kimberly S. | |
dc.contributor.author | Nauta, Haring J.W. | |
dc.contributor.author | Ding, Dale | |
dc.contributor.author | James, Robert F. | |
dc.contributor.department | Neurological Surgery, School of Medicine | en_US |
dc.date.accessioned | 2023-07-07T13:09:35Z | |
dc.date.available | 2023-07-07T13:09:35Z | |
dc.date.issued | 2021 | |
dc.description.abstract | Ruptured vertebrobasilar dissecting aneurysms require urgent, often challenging treatment as they have with a high re-hemorrhage rate within the first 24 hours. The patient is a 57-year-old woman who presented with severe-sudden onset headache. Further work up showed a ruptured dissecting aneurysm of the caudal loop of the posterior inferior cerebellar artery (PICA) with associated narrowing distally, in the ascending limb. The aneurysm was immediately occluded with a Woven Endobridge (WEB) device (MicroVention, Tustin, CA, USA) while flow diversion treatment of the diseased ascending limb was postponed. Follow-up angiography three months later showed complete occlusion of the aneurysm, as well as healing of the diseased distal vessel, obviating the need for further intervention. WEB embolization of a ruptured dissecting posterior circulation aneurysm provided an excellent outcome for this patient. | en_US |
dc.identifier.citation | Khattar NK, White AC, Cruz AS, et al. Woven Endobridge device for treatment of dissection-related PICA aneurysm. Interv Neuroradiol. 2021;27(3):388-390. doi:10.1177/1591019920968349 | en_US |
dc.identifier.uri | https://hdl.handle.net/1805/34203 | |
dc.language.iso | en_US | en_US |
dc.publisher | Sage | en_US |
dc.relation.isversionof | 10.1177/1591019920968349 | en_US |
dc.relation.journal | Interventional Neuroradiology | en_US |
dc.rights | Publisher Policy | en_US |
dc.source | PMC | en_US |
dc.subject | PICA aneurysm | en_US |
dc.subject | Posterior inferior cerebellar artery | en_US |
dc.subject | Woven Endobridge | en_US |
dc.subject | WEB device | en_US |
dc.subject | Aneurysm | en_US |
dc.subject | Dissection | en_US |
dc.title | Woven Endobridge device for treatment of dissection-related PICA aneurysm | en_US |
dc.type | Article | en_US |
ul.alternative.fulltext | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8190937/ | en_US |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Woven Endobridge device for treatment of dissection-related PICA aneurysm - PMC.pdf
- Size:
- 537.68 KB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.99 KB
- Format:
- Item-specific license agreed upon to submission
- Description: